Development of a Digital Chest Phantom for Studies on Energy Subtraction Techniques
نویسندگان
چکیده
منابع مشابه
Evaluation of a quality control phantom for digital chest radiography
RATIONALE AND OBJECTIVES To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects pla...
متن کاملA study on slab-wooden dust-slab phantom for the development of thorax phantom
Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab-wooden dust (pine)-SP34 slab (SWS) heterogeneous phantom. Materials and Methods: Th...
متن کاملeffect of oral presentation on development of l2 learners grammar
this experimental study has been conducted to test the effect of oral presentation on the development of l2 learners grammar. but this oral presentation is not merely a deductive instruction of grammatical points, in this presentation two hypotheses of krashen (input and low filter hypotheses), stevicks viewpoints on grammar explanation and correction and widdowsons opinion on limited use of l1...
15 صفحه اولDevelopment of a 4D numerical chest phantom with customizable breathing.
Respiratory movement information is useful for radiation therapy, and is generally obtained using 4D scanners (4DCT). In the interest of patient safety, reducing the use of 4DCT could be a significant step in reducing radiation exposure, the effects of which are not well documented. The authors propose a customized 4D numerical phantom representing the organ contours. Firstly, breathing movemen...
متن کاملIn‐house development of a neonatal chest simulation phantom
The aim of the study was to design and construct an anatomical and radiological phantom of a neonatal chest for investigating image quality and patient entrance surface dose (ESD). The density, elemental composition, scatter, attenuation, and absorption characteristics of different possible substitute materials were compared to that of neonatal tissues for radiological equivalence. Availability...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 2014
ISSN: 0369-4305,1881-4883