Development and Validation of Stability Indicating RP-HPLC Method for the Simultaneous Determination of Cabotegravir and Rilpivirine in Bulk and Injection Dosage Form

نویسندگان

چکیده

A simple, sensitive, specific, accurate, and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of cabotegravir rilpivirine in injection dosage form, using a Waters Model No.2695 series compact system fitted with Agilent - C18 column (BDS) (150 X 4.6 mm, 5μm) mobile composed 0.01N KH2PO4 buffer (pH: 4.8): acetonitrile (70:30v/v). The 260 nm wavelength chosen. retention times were found to be 2.30 3.187 minutes, respectively. Linearity established range 25-150 µg/mL 37.5-225µg/mL respectively: correlation coefficient (r2) 0.9999 both drugs. Cabotegravir have %RSDs 0.4 0.3 respectively, precision. proposed methods intra- inter-day precision assessments showed relative standard deviation (%RSD) below maximum permitted level 2.0. Accuracy carried out triplicate, percentage recovery 100.25% 99.79% rilpivirine, limit detection quantification 0.24 0.74 μg/mL, respectively 1.10 3.34 Both medications put stress conditions, including thermal, acidic, basic, oxidative, photolytic stress. findings demonstrated that, exception heat, UV, neutral environments, considerable degradation oxidative conditions where good separation drug peaks seen presence products. As result, this technique can used quantitatively analyze bulk forms. Keywords: Cabotegravir, RP HPLC, Rilpivirine, ICH guidelines

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

RP-HPLC method development and validation for determination of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms

A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 colum...

متن کامل

Stability Indicating Rp-hplc Method for Simultaneous Determination of Aspirin and Clopidogrel in Dosage Form

Stability-indicating High Performance Liquid Chromatographic (HPLC) method was developed for simultaneous Aspirin and Clopidogrel, A Phenomenex Gemini C-18, 5 μm column having 250mm x 4.6 mm i.d. in isocratic mode, with mobile phase containing buffer solution 0.3% orthophosphoric acid : acetonitrile (65: 35, v/v). The flow rate was 1 ml/min and effluents were monitored at 266 nm. For linearity ...

متن کامل

RP-HPLC method development and validation for determination of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms

A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 colum...

متن کامل

Stability Indicating RP-HPLC Method for Simultaneous Determination of Simvastatin and Ezetimibe from Tablet Dosage Form

A simple, specific and sensitive reverse phase high performance liquid chromatographic method was developed and validated for simultaneous determination of ezetimibe and simvastatin from pharmaceutical dosage forms. The method uses C18 ODS Hypersil column and isocratic elution. The mobile phase composed of acetonitrile:phosphate buffer (pH 4.5, 0.01M) in the ratio of 65:35 v/v was used at a flo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Pharmaceutical Research

سال: 2022

ISSN: ['2573-962X']

DOI: https://doi.org/10.18579/jopcr/v21i4.22.15