Development and Validation of RP-HPLC Method for Estimation of Amlodipine Besylate and Celecoxib in Pharmaceutical Formulation
نویسندگان
چکیده
منابع مشابه
Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector
Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...
متن کاملSimultaneous Estimation of Amlodipine Besylate and Indapamide in a Pharmaceutical Formulation by a High Performance Liquid Chromatographic (RP-HPLC) Method
An isocratic reversed-phase liquid chromatograpic assay method was developed for the quantitative determination of amlodipine besylate (AML) and indapamide (IND) in combined dosage form. A Brownlee C-18, 5 μm column with a mobile phase containing 0.02 M potassium dihydrogen phosphate-methanol (30+70, v/v) total pH-adjusted to 3 using o-phosphoric acid was used. The flow rate was 1.0 mL min(-1) ...
متن کاملDevelopment and Validation of RP-HPLC Method for Simultaneous Estimation of Enalapril Maleate and Amlodipine Besylate in Combined Dosage form
Article history: Received on: 08/09/2012 Revised on: 19/09/2012 Accepted on: 24/09/2012 Available online: 28/09/2012 A simple, precise and rapid reverse-phase HPLC method has been developed and subsequently validated for the simultaneous estimation of Amlodipine besylate and Enalapril maleate from their combination drug product. The proposed RP-HPLC method utilizes a Phenomenex C18, 5 μm, 250 m...
متن کاملDevelopment and Validation of Rp-hplc Method for Simultaneous Estimation of Lisinopril and Amlodipine Besylate in Tablet Dosage Form
A simple, specific, precise, and accurate reversed-phase HPLC method was developed and validated for simultaneous estimation of lisinopril and amlodipine besylate in tablet dosage forms. The separation was achieved by Hypersil ODS-BP C18 column (250 mm × 4.6 mm; 5.0 μm) using methanol: phosphate buffer at pH 6 adjusted with orthophosphoric acid (30: 70, v/v) as eluent, at a flow rate of 1 mL/mi...
متن کاملSimultaneous Estimation of Telmisartan and Amlodipine Besylate in Pharmaceutical Dosage Form by Rp – Hplc
The chromatographic analysis was performed on ODS symmetry C18 column (150 × 4.6 mm, 5 μ particle size) with mobile phase consisting of acetonitrile and phosphate buffer (pH 4.0) in the ratio of 60:40 v/v, at a flow rate of 1.2 mL/min and eluents monitored at 237 nm. The method was validated for linearity, accuracy, precision, robustness and application for assay as per International Conference...