Development and Validation of RP-HPLC Method for Estimation of Amlodipine Besylate and Celecoxib in Pharmaceutical Formulation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...

متن کامل

Simultaneous Estimation of Amlodipine Besylate and Indapamide in a Pharmaceutical Formulation by a High Performance Liquid Chromatographic (RP-HPLC) Method

An isocratic reversed-phase liquid chromatograpic assay method was developed for the quantitative determination of amlodipine besylate (AML) and indapamide (IND) in combined dosage form. A Brownlee C-18, 5 μm column with a mobile phase containing 0.02 M potassium dihydrogen phosphate-methanol (30+70, v/v) total pH-adjusted to 3 using o-phosphoric acid was used. The flow rate was 1.0 mL min(-1) ...

متن کامل

Development and Validation of RP-HPLC Method for Simultaneous Estimation of Enalapril Maleate and Amlodipine Besylate in Combined Dosage form

Article history: Received on: 08/09/2012 Revised on: 19/09/2012 Accepted on: 24/09/2012 Available online: 28/09/2012 A simple, precise and rapid reverse-phase HPLC method has been developed and subsequently validated for the simultaneous estimation of Amlodipine besylate and Enalapril maleate from their combination drug product. The proposed RP-HPLC method utilizes a Phenomenex C18, 5 μm, 250 m...

متن کامل

Development and Validation of Rp-hplc Method for Simultaneous Estimation of Lisinopril and Amlodipine Besylate in Tablet Dosage Form

A simple, specific, precise, and accurate reversed-phase HPLC method was developed and validated for simultaneous estimation of lisinopril and amlodipine besylate in tablet dosage forms. The separation was achieved by Hypersil ODS-BP C18 column (250 mm × 4.6 mm; 5.0 μm) using methanol: phosphate buffer at pH 6 adjusted with orthophosphoric acid (30: 70, v/v) as eluent, at a flow rate of 1 mL/mi...

متن کامل

Simultaneous Estimation of Telmisartan and Amlodipine Besylate in Pharmaceutical Dosage Form by Rp – Hplc

The chromatographic analysis was performed on ODS symmetry C18 column (150 × 4.6 mm, 5 μ particle size) with mobile phase consisting of acetonitrile and phosphate buffer (pH 4.0) in the ratio of 60:40 v/v, at a flow rate of 1.2 mL/min and eluents monitored at 237 nm. The method was validated for linearity, accuracy, precision, robustness and application for assay as per International Conference...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Drug Delivery and Therapeutics

سال: 2020

ISSN: 2250-1177

DOI: 10.22270/jddt.v10i6.4521