High performance liquid chromatography (HPLC) is an integral analytical tool in assessing drug product stability. HPLC methods should be able to separate, detect, and quantify the various drug-related degradants that can form on storage or manufacturing, plus detect and quantify any drug-related impurities that may be introduced during synthesis. Forced degradation studies of new chemical entit...
متن کاملDevelopment and validation of a stability indicating RP-HPLC method for the determination of Rufinamide
A stability-indicating RP-HPLC method was developed and validated for the determination of Rufinamide in tablet dosage forms using C 18 column (250 mm×4.6 mm, 5 μm) with mobile phase consisting of water-acetonitrile (40:60, v/v) with a flow rate of 0.8 mL/min (UV detection 215 nm). Linearity was observed over the concentration range 1.0-200 μg/mL (R2=0.9997) with regression equation y=113190 x+...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of stability-indicating HPLC method for simultaneous determination of meropenem and potassium clavulanate.
A stability-indicating LC assay method was developed and validated for a simultaneous determination of meropenem and potassium clavulanate in the presence of degradation products formed during acid-base hydrolysis, oxidation and thermolysis. The isocratic RP-HPLC method was developed with a LiChrospher RP-18 (250 mm x 4.6 mm, 5 microm) column and gradient elution of 12 mmol/L ammonium acetate a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Chinese Chemical Society
سال: 2011
ISSN: 0009-4536
DOI: 10.1002/jccs.201190004