Development and Validation of a Fluorescent Microsphere Immunoassay for Soluble CD30 Testing

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and validation of a fluorescent microsphere immunoassay for soluble CD30 testing.

Testing for soluble CD30 (sCD30), an indicator of Th2 immune response, is a useful prognostic marker in solid organ transplantation, lymphoproliferative disorders, autoimmunity, and various parasitic diseases. In this study we report the development and validation of a fluorescent microsphere immunoassay for the detection of sCD30 in serum, plasma, and culture supernatants. The dynamic range of...

متن کامل

Evaluation of a multiplex fluorescent microsphere immunoassay for the determination of epstein-barr virus serologic status.

Epstein-Barr virus (EBV), a human herpesvirus, affects up to 95% of adults. Diagnosis of acute EBV infection can be challenging and often relies on the serologic antibody pattern to 3 distinct antigens, most often determined by indirect fluorescent antibody (IFA), enzyme-linked immunosorbent assays (ELISAs), and, more recently, multiplex assays. We compared a multiplex assay for the simultaneou...

متن کامل

Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokines in human serum.

While modern immunoassays provide sensitive and specific means for the quantitation of cytokines in biological fluids, heterophile antibodies are still a well-recognized cause of interference in the measurement of cytokines in these assays. We have developed a multiplexed fluorescent microsphere immunoassay for the simultaneous quantification of 10 cytokines in only 75 microl of serum. During t...

متن کامل

Simultaneous detection and quantification of six equine cytokines in plasma using a fluorescent microsphere immunoassay (FMIA)

Cytokines are cell signalling proteins that mediate a number of different physiological responses. They are also biomarkers for inflammatory conditions and potential diagnostic references for diseases. Until recently, simultaneous quantification of cytokine profiles had not been possible. Now however, fluorescent microsphere immunoassays (FMIA) are able to measure multiple cytokines in a single...

متن کامل

A multiplexed fluorescent microsphere immunoassay for antibodies to pneumococcal capsular polysaccharides.

We developed a multiplexed indirect immunofluorescent assay for antibodies to pneumococcal polysaccharides (PnPs) based on the Luminex multiple analyte profiling system (Luminex, Austin, TX). The assay simultaneously determines serum IgG concentrations to 14 PnPs serotypes: 1, 3, 4, 5, 6B, 7F, 8, 9N, 9V, 12F; 14, 18C, 19F, and 23F. To assess the specificity of the multiplexed assay for each ind...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical and Vaccine Immunology

سال: 2009

ISSN: 1556-6811,1556-679X

DOI: 10.1128/cvi.00047-09