Development and Characterization of Real-Time Wide-Energy Range Personal Neutron Dosimeter.
نویسندگان
چکیده
منابع مشابه
Linearity response characterization of Polystyrene/ Graphene oxide nanocomposite as real-time dosimeter for therapeutic purposes
Introduction: In recent years, one of the emerging two dimensional (2D) carbon based nano- materials namely Graphene Oxide has been incorporated into polymeric matrices to enhance the electrical properties of the composites. The electrical conductivity of Graphene Oxide is excellently used in fabricating polymer-based sensors, energy-related systems, biotechnology, anti-statics...
متن کاملDevelopment and Characterization of a Neutron Personal Dose Equivalent Monitor
The authors developed a new neutron-measuring instrument that was designed to measure a neutron personal dose equivalent, Hp(10). This instrument is composed of a conventional moderator-based neutron dose equivalent meter and a neutron shield made of borated polyethylene which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP cal...
متن کاملA Novel Neutron Dosimeter
Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...
متن کاملSimulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملCharacterization of the energy response and backscatter contribution for two electronic personal dosimeter models
We characterized the energy response of personal dose equivalent (Hp(10) in mrem) and the contribution of backscatter to the readings of two electronic personal dosimeter (EPD) models with radionuclides commonly used in a nuclear medicine clinic. The EPD models characterized were the RADOS RAD-60R, and the SAIC PD-10i. The experimental setup and calculation of EPD energy response was based on A...