Developing Pulsatile Flow in a Deployed Coronary Stent
نویسندگان
چکیده
منابع مشابه
Developing pulsatile flow in a deployed coronary stent.
A major consequence of stent implantation is restenosis that occurs due to neointimal formation. This patho-physiologic process of tissue growth may not be completely eliminated. Recent evidence suggests that there are several factors such as geometry and size of vessel, and stent design that alter hemodynamic parameters, including local wall shear stress distributions, all of which influence t...
متن کاملDeveloped pulsatile flow in a deployed coronary stent.
The patho-physiologic process of restenosis and tissue growth may not be completely eliminated and is the primary concern of clinicians performing angioplasty and stent implantation procedures. Recent evidence suggests that the restenosis process is influenced by several factors: (1) geometry and size of vessel; (2) stent design; and (3) it's location that alter hemodynamic parameters, includin...
متن کاملA pulsatile developing flow in a bend
Low frequency pulsatile flow of an incompressible viscous fluid has been numerically investigated in a rigid 90° bend of circular cross-section, using the finite-volume method. The governing parameters are as follows : amplitude ratio of 1.25, Womersley
متن کاملExtraction of a Fully Deployed Coronary Stent during Retrieval of Another Dislodged Stent
Coronary stent dislodgement is a rare and serious complication of percutaneous coronary intervention and is associated with major adverse cardiac events. Successful retrieval of the stent is recommended in this situation because it is important for the prognosis. Recently, a patient was referred to our hospital with a dislodged coronary stent. When attempting to percutaneously extract the dislo...
متن کاملMultiphase hemodynamic simulation of pulsatile flow in a coronary artery.
A multiphase transient non-Newtonian three-dimensional (3-D) computational fluid dynamics (CFD) simulation has been performed for pulsatile hemodynamics in an idealized curved section of a human coronary artery. We present the first prediction, to the authors' knowledge, of particulate buildup on the inside curvature using the multiphase theory of dense suspension hemodynamics. In this study, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Biomechanical Engineering
سال: 2006
ISSN: 0148-0731
DOI: 10.1115/1.2194067