Developing an Electrical System toward the Prevention of Heat Ventilation Air Conditioning Contamination

نویسندگان

چکیده

Biofilms comprise diverse bacteria and fungi with slime material, especially in humid conditions. The surface of the heat ventilation air conditioning (HVAC) system, at evaporator, is high moisture conditions due to compression relaxation refrigerant. electrically polarized molecules, which include polysaccharide, DNA, liposome, amino acids. Thus, when an electric field applied biofilms, creates electrostatic force that enhances destruction biofilms results detachment from surface. principles are known as bioelectric effect. A new (BE) technology has been developed focused on optimization electrical energy for biofilm removal, its efficacy previously demonstrated. In this work, a prototype BE device HVAC application fabricated tested. Escherichia coli (E. coli) were utilized standard model evaporator. demonstrate was one hour, approximately 81.8% total removed. Furthermore, live cells reduced by 71.4% under device, compared non-treated biofilms.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

Determining the optimal size of a ground source heat pump within an air-conditioning system with economic and emission considerations

One of the most challenging issues in modern-day building energy management involves equipping the buildings with more energy efficient facilities. In this paper, a hybrid system for cooling/heating for a residential building is developed and optimized. The system consists of a ground source heat pump (GSHP) as well as an electric chiller (EC) and boiler. The model is implemented in MATLAB ...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

Performance Improvement of an Air Conditioning System Using Matrix Heat Exchanger

–The objective of this work is to study the performance of a split air conditioning system with and without a Matrix Heat Exchanger (MHE) .The experiment was done using HFC134a as the refrigerant and Polyol-ester oil (POE) as the conventional lubricant in the air conditioning system. The performance of the split air conditioning system with HFC134a/POE oil system was compared with HFC134a/POE o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2022

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app122211842