Developing a Treatment Planning Software Based on TG-43U1 Formalism for Cs-137 LDR Brachytherapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a Treatment Planning Software Based on TG-43U1 Formalism for Cs-137 LDR Brachytherapy

BACKGROUND The old Treatment Planning Systems (TPSs) used for intracavitary brachytherapy with Cs-137 Selectron source utilize traditional dose calculation methods, considering each source as a point source. Using such methods introduces significant errors in dose estimation. As of 1995, TG-43 is used as the main dose calculation formalism in treatment TPSs. OBJECTIVES The purpose of this stu...

متن کامل

developing a treatment planning software based on tg-43u1 formalism for cs-137 ldr brachytherapy

conclusions according to the results, the old dosimetry formalisms, overestimate the dose especially towards the applicator’s tip. while the tg-43u1 based software perform the calculations more accurately. results for a typical arrangement of 10 active pellets in the applicator, the percentage difference between doses obtained by the new algorithm at 1cm distance from the tip of the applicator ...

متن کامل

Updating the Planar Patterson-Parker Table for Ir-192 and Cs-137 Brachytherapy Sources Using the Most Recent TG-43U1 Recommended Dosimetric Parameters

Background: The Patterson-Parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. These tables were created using the dosimetric data for 226Ra that was determined in air and were utilized for dose calculations around implants with Ra-equivalent radionuclides such as 137Cs and 192Ir. Therefore, the differences of the tissue attenuation ...

متن کامل

Simulation of the shielding effects of an applicator on the AAPM TG-43 parameters of CS-137 Selectron LDR brachytherapy sources

Background: The dose rate distribution delivered by a low dose rate 137Cs pellet source, a spherical source used within the source trains of the Selectron gynecological brachytherapy system, was investigated using the MCNP4C Monte Carlo code. Materials and Methods: The calculations were performed in both water and Plexiglas and the absolute dose rate distribution for a single pellet s...

متن کامل

Erratum: "TG-43 U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source".

PURPOSE Brachytherapy treatment has been a cornerstone for management of various cancer sites, particularly for the treatment of gynecological malignancies. In low dose rate brachytherapy treatments, 137Cs sources have been used for several decades. A new 137Cs source design has been introduced (model 67-6520, source B3-561) by Isotope Products Laboratories (IPL) for clinical application. The g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Iranian Red Crescent Medical Journal

سال: 2013

ISSN: 2074-1804,2074-1812

DOI: 10.5812/ircmj.4938