Developed Hybrid Model for Propylene Polymerisation at Optimum Reaction Conditions
نویسندگان
چکیده
منابع مشابه
Developed Hybrid Model for Propylene Polymerisation at Optimum Reaction Conditions
A statistical model combined with CFD (computational fluid dynamic) method was used to explain the detailed phenomena of the process parameters, and a series of experiments were carried out for propylene polymerisation by varying the feed gas composition, reaction initiation temperature, and system pressure, in a fluidised bed catalytic reactor. The propylene polymerisation rate per pass was co...
متن کاملZirconium and hafnium Salalen complexes in isospecific polymerisation of propylene.
The activity of dibenzylzirconium and dibenzylhafnium Salalen complexes in polymerisation of propylene with MAO as a cocatalyst is described. Three Salalen ligand precursors combining a bulky alkyl group (1-adamantyl) on the imine-side phenol and electron withdrawing halo groups of different sizes on the amine-side phenol were explored. All metal complexes were obtained as single diastereomers....
متن کاملCreatine kinase: re-examination of optimum reaction conditions.
I have re-examined optimum reaction conditions for measurement of creatine kinase (EC 2.7.3.2). The optimum pH is 6.45, and 2,2-bis(hydroxymethyl)-2,2',2''-nitrotriethanol acetate, 200 mmol/liter, is the buffer of choice. Thioglycerol, 20 mmol/liter, is superior for both in-assay reactivation and for storage stability of sera. Fluoride, 25 mmol/liter, a broad inactivator of adenylate kinase (EC...
متن کاملCreatine kinase in serum: 1. Determination of optimum reaction conditions.
To establish optimum conditions for creatine kinase (EC 2.7.3.2) activity measurement with the creatine phosphate in equilibrium creatine reaction, we re-examined all kinetics factors relevant to an optimal and standardized enzyme assay at 30 and 25 degrees C. We determined the pH optimum in vaious buffers, considering the effect of the type and concentration of the buffer, as well as the influ...
متن کاملOptimum conditions for adsorptive storage.
The storage of gases in porous adsorbents, such as activated carbon and carbon nanotubes, is examined here thermodynamically from a systems viewpoint, considering the entire adsorption-desorption cycle. The results provide concrete objective criteria to guide the search for the "Holy Grail" adsorbent, for which the adsorptive delivery is maximized. It is shown that, for ambient temperature stor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Polymers
سال: 2016
ISSN: 2073-4360
DOI: 10.3390/polym8020047