Determining total I-131 activity within a VoI using SPECT, a UHE collimator, OSEM, and a constant conversion factor
نویسندگان
چکیده
منابع مشابه
Recovery of total I-131 activity within focal volumes using SPECT and 3D OSEM.
We experimentally investigated the SPECT recovery of I-131 activity in multiple spheres located simultaneously at different locations within a cylindrical phantom that had an elliptical cross section. The sphere volumes ranged from 209 cc down to 4.2 cc. A Prism 3000 camera and two types of parallel-hexagonal-hole collimation were employed: high energy (HE) and ultra high energy (UHE). Using ap...
متن کاملf/sla from learner perspectives: a social activity or a cognitive process
in the past couple of decades sociocultural theory of sla and its implications in efl contexts have attracted attentions of research circles worldwide and aroused some controversies. firth and wagner (1997) have questioned the principles of the cognitive view which gives importance to mental constructs in favor of sociocultural view which highlights social and contextual constructs. but if soci...
15 صفحه اولSpace-Alternating Generalized EM (SAGE) algorithm with attenuation correction but without detector-response modeling
We calibrated a scintillation camera for the counts-to-activity conversion factor, CF, by measuring a phantom consisting of a sphere containing a known 131-I activity placed within an elliptical cylinder. Within a 3D OSEM reconstruction algorithm, we employed a depth-dependent detector-response model based on smooth fits to the pointsource-response function. Using the ultra-high-energy (UHE) co...
متن کاملDe-Noising SPECT Images from a Typical Collimator Using Wavelet Transform
Introduction: SPECT is a diagnostic imaging technique the main disadvantage of which is the existence of Poisson noise. So far, different methods have been used by scientists to improve SPECT images. The Wavelet Transform is a new method for de-noising which is widely used for noise reduction and quality enhancement of images. The purpose of this paper is evaluation of noise reduction in SPECT ...
متن کاملSPECT using a specially designed cone beam collimator.
A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 2004
ISSN: 0018-9499
DOI: 10.1109/tns.2004.829605