Determining optimal neutral reactor to limit overvoltages and duration of secondary arc of transmission lines
نویسندگان
چکیده
Even though shunt compensation of transmission lines (TLs) is a common practice to limit the overvoltages stemming from Ferranti effect, it may cause transient and steady-state resonant when one phase left open due single-pole-open condition following temporary phase-to-ground (Ph-g) fault. Furthermore, existing reactors potentially increase duration secondary arc current at fault point hence prevent offering fast single-pole reclosing. To exploit mentioned issues, in recent studies, neutral reactor introduced, which installed reactors; nonetheless, obtaining appropriate amount remarkably challenging. In this paper, an optimal (ONR) determined based on optimization problem, minimizes cost subject limiting both current. modelling, Laplace domain employed rather than phasor consider conditions since technique allows having better control over as well arc.
منابع مشابه
the role of russia in transmission of energy from central asia and caucuses to european union
پس ازفروپاشی شوروی،رشد منابع نفت و گاز، آسیای میانه و قفقاز را در یک بازی ژئوپلتیکی انرژی قرار داده است. با در نظر گرفتن این منابع هیدروکربنی، این منطقه به یک میدانجنگ و رقابت تجاری برای بازی های ژئوپلتیکی قدرت های بزرگ جهانی تبدیل شده است. روسیه منطقه را به عنوان حیات خلوت خود تلقی نموده و علاقمند به حفظ حضورش می باشد تا همانند گذشته گاز طبیعی را به وسیله خط لوله مرکزی دریافت و به عنوان یک واس...
15 صفحه اولmorphology, geochemistry, mineralogy, and micromorphology of soils of hormozgan province in relation to parent materials
ویژگی های زمین شیمیایی، کانی شناسی، و میکرومورفولوژیکی خاک ها و سنگ مادر مربوطه در منطقه بین بخش های جنوبی زاگرس و خلیج فارس تا دریای عمان(استان هرمزگان، ایران) مورد بررسی قرار گرفت. هدف های این مطالعه شناسایی تغییرات در خصوصیات فیزیکی، شیمیایی، و ترکیب کانی شناسی خاک، مطالعه میکرومورفولوژی و تکامل خاک، و بررسی توزیع عنصر خاک بر اساس هوازدگی، پروسه های خاک و زمین شناسی جهت توصیف اثرات مواد مادر...
15 صفحه اولEstimation of magnitude and time duration of temporary overvoltages using ANN in transmission lines during power system restoration
In most countries, the main step in the process of power system restoration, following a complete/partial blackout, is energization of primary restorative transmission lines. Artificial neural network (ANN) is employed for performing a nonlinear input–output mapping in this work, in order to estimate the temporary overvoltages (TOVs) due to transmission lines energization. In the proposed metho...
متن کاملthe innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran
آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...
15 صفحه اولa comparison of teachers and supervisors, with respect to teacher efficacy and reflection
supervisors play an undeniable role in training teachers, before starting their professional experience by preparing them, at the initial years of their teaching by checking their work within the proper framework, and later on during their teaching by assessing their progress. but surprisingly, exploring their attributes, professional demands, and qualifications has remained a neglected theme i...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Iet Generation Transmission & Distribution
سال: 2022
ISSN: ['1751-8687', '1751-8695']
DOI: https://doi.org/10.1049/gtd2.12737