Determined the bulk etch rate VB by different methods for nuclear track detector CR-39

نویسندگان

چکیده

In this study, the bulk etch rate (VB) was measured by three different methods forCR-39 with a thickness of 200µm and an area (1 × 1 cm2), where CR_39 irradiated through from Am241source energy alpha particles is 2.6MeV at angle fall perpendicular to surface CR-39 detector, detector etching (NaOH) concentration 6.25N (70 ± 1°C) showing effects formed on time periods ranging (0.25h) were photographed eching times using optical microscope type (XSZ-H Series Biological Microscope) equipped digital camera (MADC_5A) connected personal computer, in order find length, diameters track detector.VB determind are: Removed method, second saturation diameter-length method (D_L method), as first does not require irradiation but other two measurement lengths And proving effect, we found that values VB for methods, removed effect ((D_L method) respectively are:, (1.206, 1.204, 1.271 (µm/h) compare results between mentioned they are close.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proton beam dosimetry by CR-39 track-etched detector

Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...

متن کامل

E ects of stirring on the bulk etch rate of CR-39 detector

It is well established that the bulk etch rates for solid state nuclear track detectors are a ected by the concentration and the temperature of the etchant. Recently, we found that the bulk etch rate for the LR 115 detector to be a ected by stirring during etching. In the present work, the e ects of stirring on the bulk etch rate of the CR-39 detector is investigated. One set of sample was etch...

متن کامل

A parameterization of nuclear track profiles in CR-39 detector

In this work, the empirical parameterization describing the alpha particles’ track depth in CR-39 detectors is extended to describe longitudinal track profiles against etching time for protons and alpha particles. MATLAB based software is developed for this purpose. The software calculates and plots the depth, diameter, range, residual range, saturation time, and etch rate versus etching time. ...

متن کامل

proton beam dosimetry by cr-39 track-etched detector

background: high and intermediate energy protons are not able to form a track in a solid state nuclear track detector (ssntd) directly. however, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a ssntd. materials and methods: the protons with primary energies of 9.6 and 30 mev available at the cyclotron accelerator with corresponding lo...

متن کامل

Bulk and track etch properties of CR-39 SSNTD etched in NaOH/ethanol

Recently, Matiullah et al. described the use of NaOH/ethanol as an etchant for the CR-39 detector, and have determined the corresponding bulk and track etch properties from the track diameter method. In the present work, the bulk and track etch properties of CR39 in NaOH/ethanol were derived from direct measurements. The bulk etch rate has been found to increase with the molarity of NaOH/ ethan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: ???? ??????? ??????

سال: 2023

ISSN: ['2664-2530', '1812-125X']

DOI: https://doi.org/10.33899/edusj.2023.137160.1297