Determination of Vessel Cross-Sectional Area by Thresholding in Radon Space

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of vessel cross-sectional area by thresholding in Radon space.

The cross-sectional area of a blood vessel determines its resistance, and thus is a regulator of local blood flow. However, the cross-sections of penetrating vessels in the cortex can be non-circular, and dilation and constriction can change the shape of the vessels. We show that observed vessel shape changes can introduce large errors in flux calculations when using a single diameter measureme...

متن کامل

Radon needlet thresholding

We provide a new algorithm for the treatment of the noisy inversion of the Radon transform using an appropriate thresholding technique adapted to a well-chosen new localized basis. We establish minimax results and prove their optimality. In particular, we prove that the procedures provided here are able to attain minimax bounds for any Lp loss. It is important to notice that most of the minimax...

متن کامل

Dominance in hands and cross-sectional area of median nerve in carpal tunnel syndrome

Introduction: Currently, neuroresearchers report that the median nerve shows severity-correlated intracarpal enlargement in idiopathic carpal tunnel syndrome (CTS) as a most common peripheral neuropathic disorder. The purpose of this paper was to investigate ultrasonography morphological findings in patients with idiopathic CTS and comparing some physical properties such as age, gender, BMI wit...

متن کامل

Measurement of pharyngeal cross-sectional area by finite element analysis.

A noninvasive measurement of pharyngeal cross-sectional area (CSA) during sleep would be advantageous for research studies. We hypothesized that CSA could be calculated from the measured pharyngeal pressure and flow by finite element analysis (FEA). The retropalatal airway was visualized by using a fiber-optic scope to obtain the measured CSA (mCSA). Flow was measured with a pneumotachometer, a...

متن کامل

Characterisation of Schlemm's canal cross-sectional area

PURPOSE To compare three methods of Schlemm's canal (SC) cross-sectional area (CSA) measurement. METHODS Ten eyes (10 healthy volunteers) were imaged three times using spectral-domain optical coherence tomography (Cirrus HD-OCT, Zeiss, Dublin, California, USA). Aqueous outflow vascular structures and SC collector channel ostia were used as landmarks to identify a reference location within the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Cerebral Blood Flow & Metabolism

سال: 2014

ISSN: 0271-678X,1559-7016

DOI: 10.1038/jcbfm.2014.67