Determination of total tin in sediments by graphite furnace atomic absorption spectrometry.
نویسندگان
چکیده
منابع مشابه
GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کاملDirect Determination of Tin in Human Hair by Graphite Furnace Atomic Absorption Spectrometry Using Air Ashing in Graphite Tube
Direct determination of tin in human hair was performed by graphite furnace atomic absorption spectrometry. Human hair was cut into 3-5 mm long and 1-2 mg of the sample was directly introduced into a pyrolytically coated graphite tube, of which the injection hole was enlarged to a diameter of approximately 5 mm. After introduction of the sample, 20 μl of 30 mg Pd/l in 1 mol/l HCl was added as a...
متن کاملUtilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کاملSlurry sampling of sediments for direct determination of Cu, Mn, Ni, Sn and Zn by graphite furnace atomic absorption spectrometry
In this study, methodologies were developed for the determination of metals (Cu, Mn, Ni, Sn and Zn) in sediments prepared as slurries, which were maintained homogeneous by the introduction of air supplied by an aquariam pump by GF AAS (Graphite Furnace Atomic Absorption Spectrometry). The optimization of the pyrolysis and atomization temperatures were done through pyrolysis and atomization temp...
متن کاملDetermination of lead in croatian wines by graphite furnace atomic absorption spectrometry.
A method has been developed for direct determination of lead in wine by graphite furnace atomic absorption spectrometry (GFAAS) with Zeeman-effect background correction. The thermal behaviour of Pb during pyrolysis and atomisation stages was investigated without matrix modifier and in the presence of Pd(NO(3))(2), Pd(NO(3))(2) + Mg(NO(3))(2) × 6H(2)O, and NH(4)H(2)PO(4) + Mg(NO(3))(2) × 6H(2)O ...