Determination of tin by graphite furnace AAS with matrix modifier.
نویسندگان
چکیده
منابع مشابه
Graphite Furnace AAS: Application of Reduced Palladium as a Chemical Modifier
Chemical modification techniques are widely used in graphite furnace atomic absorption spectrometry (GFAAS). Palladium is a very effective chemical modifier and can be used to stabilize many elements to several hundred degrees higher than the temperatures possible with current methods [1-9]. Of the elements tested, the greatest temperature shifts are achieved for the semi-metallic elements such...
متن کاملDirect Determination of Tin in Human Hair by Graphite Furnace Atomic Absorption Spectrometry Using Air Ashing in Graphite Tube
Direct determination of tin in human hair was performed by graphite furnace atomic absorption spectrometry. Human hair was cut into 3-5 mm long and 1-2 mg of the sample was directly introduced into a pyrolytically coated graphite tube, of which the injection hole was enlarged to a diameter of approximately 5 mm. After introduction of the sample, 20 μl of 30 mg Pd/l in 1 mol/l HCl was added as a...
متن کاملThe Reduction of Matrix Interferences Utilizing the Platform in Graphite Furnace AAS
Graphite furnace techniques are characterized by excellent analytical sensitivity and are the methods of choice for the determination of trace elements in various environmental, biological, and clinical samples. However, they can be plagued by matrix interferences which complicate methods development and sample analysis. This is particularly true for the determination of volatile elements in co...
متن کاملLarge-volume injection electrothermal AAS combined with tungsten-treated pyrolytic graphite furnace: determination of cadmium in tap, snow and river water samples with phosphate modifier.
A large-volume (100 microl) injection-ETAAS with W-treated PG furnace combined with a phosphate modifier was applied to the determination of unpolluted levels of Cd in tap, snow and river-water samples. The limit of detection of 1.1 ng l(-1) was observed for a 4 w/v% NH4H2PO4 modifer. Matrix interference studies were tested for major ion species well found in fresh water. The direct determinati...
متن کاملDEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE
Aluminium determination was carried out in serum and dialysis fluid by a simple and reliable method of nameless atomic absorption with graphite furnace . . No preparatory procedures are required for water and dialysis fluid. In this method serum was mixed with 0.2% HNO, to allow complete combustion of the samples in order to improve analytical precision. The method has a sensitivity of 15 p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1987
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.36.10_597