Determination of Tilmicosin in Bovine Milk by Liquid Chromatography with Ultraviolet Detection

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of tilmicosin residues in cow and sheep milk by liquid chromatography.

This method was developed and validated to detect and quantitate tilmicosin residues in cow milk over a range of 0.010-10 microg/mL, and in sheep milk over a range of 0.025-0.5 microg/mL. The procedure involves extracting the milk sample with acetonitrile and using a C18 cartridge to perform a solid-phase extraction cleanup of the extract. A reversed-phase gradient liquid chromatography method ...

متن کامل

Determination of Astaxanthin in Trout by High Performance Liquid Chromatography Coupled with Visible Detection

Background: Astaxanthin is widely and naturally distributed in marine animals including, crustaceans, such as shrimp, crabs, and fish, such as salmon and trout. Methods: A total of 20 trout samples were collected from local market and were analyzed for astaxanthin via HPLC-UV. Analyte extraction was done by water, methanol, dichloromethane, and acetonitrile 4.5:85:5:45.5, v/v/v/v. Results: Desp...

متن کامل

Determination of chlorpheniramine maleate and tincture ipecac in dosage form by liquid chromatography with ultraviolet detection.

A procedure was developed and validated for measuring chlorpheniramine maleate and tincture ipecac (as emetine hydrochloride) by reversed-phase liquid chromatography with methanol-10 mM sodium heptanesulfonate (20 + 30) as the mobile phase; the pH was adjusted to 4 with acetic acid, and the flow rate was at 1.5 mL/min, with ultraviolet detection at 254 nm. Propyl paraben was used as the interna...

متن کامل

Determination of rifampin in human plasma by high-performance liquid chromatography with ultraviolet detection.

A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifampin in human plasma. Rifampin and sulindac (internal standard) are extracted from human plasma using a C2 Bond Elut extraction column. A 100-microliter volume of 0.1 M HCl is added to the plasma before extraction to increase the retention of the compounds on the ext...

متن کامل

Quantitative Determination of Pravastatin in Pharmaceutical Dosage Forms by High-Performance Liquid Chromatography with Ultraviolet Detection

A simple, sensitive and precise high-performance liquid chromatographic formulations assay for pravastatin (PVS) is described. Good chromatographic separation was achieved using a Teknokroma C8 (5 μm, 25cm × 4.6mm) column and a mobile phase consisting of 10mM ammonium acetate: methanol: triethylamine (40:60:0.17 v/v/v) while at a flow-rate of 1.0 mL min(-1). PVS was detected at 239 nm and was e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of AOAC INTERNATIONAL

سال: 1996

ISSN: 1060-3271,1944-7922

DOI: 10.1093/jaoac/79.3.652