Determination of Anions in Acid Rain by Ion Chromatography

INTRODUCTION The increase in acidity of wet and dry atmospheric depositions has been attributed to the increase of SO 2 and NO 2 emissions from stationary and mobile pollution sources. The acid rain problem has reached dramatic proportions throughout many regions of the United States, Europe, Canada, and Japan. Monitoring air and rain is essential, not only for assessing the effects of pollutan...

متن کامل

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

INTRODUCTION Hexavalent chromium, Cr(VI), is the most toxic form of the metal chromium, a primary drinking water contaminant in the U.S. Dissolved hexavalent chromium can be determined as chromate (CrO 4 ) by ion chromatography in drinking water, groundwater, and industrial wastewater effluents as described in U.S. EPA Method 218.6 and Dionex Technical Note 26. Dionex Technical Note 26 uses a 2...

متن کامل

Determination of Bromate in Water Using Ion Chromatography

Ozone is a powerful drinking water disinfectant that is effective in treating chlorine resistant organisms, such as Cryptosporidia. For bottled water, ozonation is generally preferred over other available disinfection treatment methods because it does not leave a taste or residual disinfectant, due to ozone’s short lifetime. However, ozonation of drinking water containing bromide can result in ...

متن کامل

Determination of sulfite in dried garlic by reversed-phase ion-pairing liquid chromatography with post-column detection.

A method is described for determining sulfite in dried garlic. Garlic is extracted with an HCl solution to inhibit the formation of allicin, which interferes with the determination of sulfite. After cleanup of the extract on a C18 solid-phase extraction column, sulfite is converted to hydroxymethylsulfonate (HMS) by adding formaldehyde and heating to 50 degrees C. HMS is determined by reversed-...

متن کامل

Thiocyanate determination by ion pair chromatography

Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania A simple and rapid ion pair chromatographic method has been developed for the determination of thiocyanate. Separation was carried out on a 25 cm × 4.6 mm Ascentis C18 column (5 μm particle size) with a mobile phase containing 2 mmol/l tetrabutylammonium (TBA)-phosphate (pH 6.5) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 1986

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.35.5_465