Determination of rare earth impurities in terbium and terbium oxide by HPLC/ICP-AES.
نویسندگان
چکیده
منابع مشابه
Anodic oxide formation on aluminium-terbium alloys
Aluminium terbium alloys were prepared by simultaneous thermal evaporation resulting in a thin film library covering a 5 to 25 at.% Tb compositional spread. Synchrotron x-ray diffraction (XRD) proves all of the alloys to be amorphous. Scanning electron microscopy (SEM) measurements reveal the structural changes upon increase in Tb content with the formation of small, Tb-rich segregations right ...
متن کاملDetermination of the Binding Constant of Terbium-Transferrin
Apotransferrin (apo Tf) in 0.1 M N-(2hydroxyethyl)piperazine-N2-ethanesulfanic acid at 25 ˚C and pH 7.4 has been titrated with acidic solution of Tb3+. The binding of Tb3+ at the two specific metal-binding sites of transferrin was followed from the changes in the difference UV spectra at 245 nm. The molar absorptivity per binding site for Tb3+...
متن کاملSpectrofluorimetric determination of cefixime using terbium-danofloxacin probe
Objective(s):Cefixime (Cfx), is a semi-synthetic third-generation oral cephalosporin antibiotic that is prescribed for the treatment of susceptible infections. There are some procedures for the determination of Cfx in pharmaceutical formulations and biological samples. Herein a spectrofluorimetric method was proposed for Cfx determination based on the fluorescence quenching of terbium-danofloxa...
متن کاملDetermination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method
A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...
متن کاملDetermination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method
A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1991
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.40.6_t125