Determination of Oestradiol-17ß in Human Serum by Isotope Dilution-Mass Spectrometry. Definitive Methods in Clinical Chemistry, II
نویسندگان
چکیده
منابع مشابه
Determination of creatinine in human serum by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, IV.
A method for the determination of creatinine in human serum by isotope dilution-mass spectrometry is described. The analytical procedure comprises the following steps: Addition of [13C,15N2 )creatinine to the serum sample; ion exchange chromatography on the cation exchange resin AG 50W-X2; formation of the trimethylsilyl derivative; gas liquid chromatography-mass spectrometry (GC-MS); selected ...
متن کاملDetermination of uric acid in human serum by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, III.
A method for the measurement of uric acid in human serum by isotope dilution-mass spectrometry is described. The analytical procedure consists of the following steps: Addition of [1,3-15N2]uric acid to the serum sample; ion exchange chromatography on AG1-X2; formation of the trimethylsilyl derivative; gas liquid chromatography-mass spectrometry (GC-MS), selected ion monitoring (SIM) at m/z-valu...
متن کاملDetermination of serum glucose by isotope dilution mass spectrometry: candidate definitive method.
We report a rather simple method to determine glucose concentration in serum, using isotope dilution mass spectrometry and [13C6]glucose as internal standard. The procedure involves a single step of sample purification and the conversion of the analyte into its aldononitrile pentaacetate. The between-day and within-day contribution to total variance for a single measurement was determined by as...
متن کاملThermal-ionization isotope-dilution mass spectrometry as a definitive method for determination of potassium in serum.
Thermal-ionization isotope-dilution mass spectrometry is a highly precise and accurate method for the determination of potassium concentrations in serum. Although not suited for routine use because of the time and expense required, the technique provides an extremely valuable tool for the characterization of reference materials and for evaluating other analytical methods. The technique has rece...
متن کاملDetermination of serum cholesterol by isotope dilution mass spectrometry with a benchtop capillary gas chromatograph/mass spectrometer: comparison with the National Reference System's Definitive and Reference Methods.
We developed an isotope dilution mass spectrometric cholesterol method with [25,26,27-13C]cholesterol as internal standard and a benchtop gas chromatograph/mass spectrometer (GC/MS) that is much easier and less time consuming than previously described Reference and Definitive Methods for cholesterol. The internal standard, cholesterol standards, and unknown specimen are delivered volumetrically...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry and Laboratory Medicine
سال: 1984
ISSN: 1434-6621,1437-4331
DOI: 10.1515/cclm.1984.22.8.551