Determination of molybdenum in natural water by solvent extraction/ICP-AES.
نویسندگان
چکیده
منابع مشابه
Determination of Boron, Phosphorus, and Molybdenum Content in Biosludge Samples by Microwave Plasma Atomic Emission Spectrometry (MP-AES)
A novel analytical method for accurate determination of boron (B), phosphorous (P), and molybdenum (Mo) content in biosludge samples based on a relatively recent analytical technique, microwave plasma atomic emission spectrometry (MP-AES), is developed in the present work. Microwave assisted acid digestion method is utilized to extract B, P, and Mo from biosludge. To demonstrate the reliability...
متن کاملDetermination of molybdenum in steel samples by ICP-AES after separation and preconcentration using nanometre-sized titanium dioxide
A sensitive and selective method has been developed for the determination of Mo in steel samples using a nanometre-sized titanium dioxide micro-column (20 mm 6 3.0 mm id) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Under the optimized conditions (pH 1.0, flow rate 1.5 mL min), Mo was retained on the column and separated from the iron matrix, then eluted with 0.5 mol L...
متن کاملSimultaneous Determination of Ba and Sr in Oilfield Produced Water by ICP-AES
Oil is an important non-renewable resource for the world. The application of alkaline-surfactant-polymer flooding has successfully enhanced the oil recovery in Chinese oilfields. The oilfield produced water is the layer water that came from the oil well along with the oil in the alkaline-surfactant-polymer flooding. Thus, the treatment process of oilfield produced water to meet the reinjection ...
متن کاملSpeciation of molybdenum in river water by size fractionation and catalytic determination.
A speciation scheme of trace molybdenum was proposed for river water based on size fractionation by filtration and ultrafiltration and the catalytic spectrophotometric determination of the reactive molybdenum concentration (CR). The total concentration (CT) of molybdenum was determined by the same method after acid decomposition to obtain the concentration (CT - CR) of unreactive molybdenum. Mo...
متن کاملmultiwavelength pectrophotometric determination of stability constants of 4-(2– thiazolylazo) resorcinol (tar) with la3+, y3+ and th4+ in organic-water mixed solvents by chemometrics method & simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares calibration method
تشکیل کمپلکس های tarبا یون های لانتانیم, ایتریم و توریم در دمای 25 درجه، قدرت یونی ثابت 0.1 مولار و در ph ثابت در مخلوط حلال های اتانول – آب و استونیتریل – آب با استفاده از روش های اسپکتروفوتومتری مورد بحث و بررسی قرار گرفت. داده های اسپکتروفوتومتری با استفاده از نرم افزار squad پردازش شدند تا ثابت های تشکیل کمپلکس اندیکاتور – فلز را محاسبه کند. نتایج نشان می دهد که درصد حلال آلی در مخلوط حلال ...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1994
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.43.1127