Determination of Member Connection Stiffness For Semi-Precast High-Rise Building
نویسندگان
چکیده
منابع مشابه
Semi-active Control of Building Structures using Variable Stiffness Device and Fuzzy Logic
Semi-active control devices, also called “Intelligent” control devices, constitute the positive aspects of both the passive and active control devices. A semi-active control strategy is similar to the active control strategy, but this control device has been shown to be more energy-efficient than active devices. A particular type of semi-active control device, the Variable Stiffness Device (VSD...
متن کاملDesign Considerations for the Connection of Precast Concrete Structures
The structural integrity of precast concrete buildings depends mainly on the connections between the precast structural components. Large precast concrete panels are used extensively in North America for low, medium, and highrise construction due to their ease and speed of assembly, and high quality control. This paper presents the results of twenty-two prototype specimens tested to investigate...
متن کاملSIMULTANOUS OPTIMIZATION OF SIZE AND CONNECTION ARRANGEMENT FOR LOW-RISE STEEL PLATE SHEAR WALL SYSTEMS
The present study is concerned with the simultaneous optimization of the size of components and the arrangement of connections for performance-based seismic design of low-rise SPSWs. Design variables include the size of beams and columns, the thickness of the infill panels, the type of each beam-to-column connection and the type of each infill-to-boundary frame connection. The objective functio...
متن کاملAdvantages and Limitations of Precast Concrete Construction in High-rise Buildings: Hong Kong Case Studies
The Hong Kong construction industry heavily relies on conventional cast insitu construction involving extensive use of wet trades and on-site construction processes. The construction activities have been described as “labour intensive, dangerous and polluting”. Recently, the use of prefabrication has increased in the building industry. This paper presents the preliminary findings of an ongoing ...
متن کاملDual Control High-rise Building for Robuster Earthquake Performance
A dual passive control system is proposed for high-rise buildings. Since the proposed system needs a substructure supporting the main building, it is usually used in high-rise residential apartment houses where a parking tower is used as the substructure. This new system consists of a base-isolation system and a building-connection system. While base-isolated buildings and interconnected buildi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOP Conference Series: Materials Science and Engineering
سال: 2019
ISSN: 1757-899X
DOI: 10.1088/1757-899x/661/1/012043