Determination of Local Structures Around Trace Transition Elements in Minerals by Anomalous X-ray Scattering and X-ray Absorption Fine Structure Analyses
نویسندگان
چکیده
منابع مشابه
Photon interference x-ray absorption fine structure
We report about a fine structure in x-ray absorption spectra, named photon interference x-ray absorption fine structure (pXAFS). pXAFS is due to the interference of x-rays inside the sample and extends across absorption edges. Using a platinum foil pXAFS was measured in a high precision absorption experiment. Excellent agreement with a theoretical pXAFS simulation is achieved in the energy rang...
متن کاملLocal structure of Pt and Pd ions in Ce(1-x)TixO2: x-ray diffraction, x-ray photoelectron spectroscopy, and extended x-ray absorption fine structure.
Ce(1-x-y)Ti(x)Pt(y)O(2-delta) (x=0.15; y=0.01) and Ce(1-x-y)Ti(x)Pd(y)O(2-delta) (x=0.25; y=0.02 and 0.05) are found to be good CO oxidation catalysts [T. Baidya et al., J. Phys. Chem. B 110, 5262 (2006); T. Baidya et al., J. Phys. Chem. C 111, 830 (2007)]. A detailed structural study of these compounds has been carried out by extended x-ray absorption fine structure along with x-ray diffractio...
متن کاملA proton induced X-ray emission (PIXE) analysis of concentration of trace elements in varicose veins
Background: Proton induced X-ray emission (PIXE) has been applied as reliable and improved techniques in this study to compare concentration of various trace elements in normal and abnormal varicose veins. Materials and Methods: Five samples from normal veins and 13 samples from varicose veins bombarded by 2.0 MeV energy proton beams produced by a Van de Graff accelerator in vacuum. T...
متن کاملDosimetry of Occupational Radiation around Panoramic X-ray Apparatus
Background: Panoramic imaging is one of the most common imaging methods in dentistry. Regarding the side-effects of ionizing radiation, it is necessary to survey different aspects and details of panoramic imaging. In this study, we compared the absorbed x-ray dose around two panoramic x-ray units: PM 2002 CC Proline (Planmeca, Helsinki, Finland) and Cranex Tome (Soredex, Helsinki, Finland).<br ...
متن کاملExtended X-ray absorption fine structure in dispersive mode
2014 It has been possible to disperse the X-ray beam provided by the storage ring DCI at LURE in order to perform fast EXAFS experiments (~ 1 s). The weak divergence of the synchrotron beam opens up the possibility of achieving a very good energy resolution. The first data collected with a solid-state detector array (RETICON) show that kinetic studies with a time scale lower than 1/10 s could b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nihon Kessho Gakkaishi
سال: 2020
ISSN: 0369-4585,1884-5576
DOI: 10.5940/jcrsj.62.76