Determination of load capacity of bored piles
نویسندگان
چکیده
منابع مشابه
Interpreting Strain Measurements from Load Tests in Bored Piles
In static load tests vibrating wire strain gages are generally used. The advantage of vibrating wire sensors over more conventional electrical resistance or semi-conductor types lies mainly in the sensor output, which is a frequency rather than a voltage or resistance. The frequency output is easier to transmit over long cables and is unaffected by voltage drops such as those which can be broug...
متن کاملPrediction of End Bearing Capacity for Pre-Bored Steel Pipe Piles Using Instrumented Spt Rods
The standard penetration test (SPT) has been widely used because of its usability, economy, and many correlations with soil properties among other factors. In SPT, hammer energy is an important factor to evaluate and calibrate N values. To measure hammer energy, an instrumented SPT rod was developed considering that stress waves transferring on rods during SPT driving are the same as stress wav...
متن کاملAssessment of load-carrying capacity of bored pile in clay soil using different methods
It is very difficult to predict the load carrying capacity of bored piles because of the Complications that may arise such as difficult ground conditions , presence of ground water, method of boring, method of concreting, quality of concrete, expertise of the construction staff, the ground conditions and the pile geometry. Therefore the Pile design must be accompanied by in situ load testing. M...
متن کاملDetermination of Lateral load Capacity of Steel Shear Walls Based on Artificial Neural Network Models
In this paper, load-carrying capacity in steel shear wall (SSW) was estimated using artificial neural networks (ANNs). The SSW parameters including load-carrying capacity (as ANN’s target), plate thickness, thickness of stiffener, diagonal stiffener distance, horizontal stiffener distance and gravity load (as ANN’s inputs) are used in this paper to train the ANNs. 144 samples data of each of th...
متن کاملPullout Capacity of Model Piles in Sand
A large scale experimental program using vertical and batter model piles in sand subjected to pull out loads has been carried out in a model tank of size 1m x 1m x 1m. Mild steel pipes of varying diameters, lengths, and shapes are used as model piles. A poorly graded river sand having specific gravity G= 2.67, Uniformity coefficient= 3.53, emax = 0.81, emin = 0.54 has been used as foundation me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PNRPU Construction and Architecture Bulletin
سال: 2014
ISSN: 2224-9826,2305-2724