Determination of lithium content of infant formulas by flame photometry.
نویسندگان
چکیده
منابع مشابه
The determination of magnesium in biological materials by flame photometry.
A method is described for the measurement of magnesium in biological materials and has been applied to the Unicam flame spectrophotometer SP 900. Samples were diluted in 10 mM strontium ethylenedinitrolo tetraacetate (EDTASr), 10 mM potassium carbonate, giving final magnesium concentrations of about 0.1 to 0.2 mM. The EDTASr almost eliminated the depression of magnesium emission by interfering ...
متن کاملThe determination of calcium in biological fluids by flame photometry.
The use of flame photometers has greatly simplified and expedited the estimation of sodium and potassium. Calcium is one of the elements which it is possible to determine by flame photometry, but little advantage has been taken of this fact in biological work for a number of reasons. The concentration of calcium in extracellular fluids is usually less than that of potassium ; a given quantity o...
متن کاملThe determination of serum bicarbonate by flame photometry.
At the present time, the applicability of the flame photometer to the clinical laboratory for determination of the cations sodium, potassium, and calcium in biological fluids has been demonstrated by numerous investigators (l-7). The determination of magnesium in blood serum and plasma by flame photometry has also been described (2, 8). However, analysis of physiologically significant anions in...
متن کاملdetermination of serum lithium by flame emission spectroscopy
lithum can be de termined both by atomic absorption spectroscopy andflame emission spectroscopy. we have used the later method with a zeiss model pmqli spectro photometer fitt ed with ante-chamber atomizer and a potensiome rric line recorder. accurate ana lysis for the clement was acco mplished due to a sophisracared measuring instrument.
متن کاملHigh aluminium content of infant milk formulas.
The aluminium content of several commercially available infant milk formulas was measured by electrothermal atomic absorption spectrometry. Results were compared with those for fresh breast milk, cow's milk, and local tap water. Differences in aluminium concentration of greater than 150-fold were found, with the lowest concentrations in breast milk.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1999
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.48.435