Determination of glucose in blood using glucose oxidase-peroxidase system and 8-hydroxyquinoline-p-anisidine.
نویسندگان
چکیده
منابع مشابه
Use of glucose oxidase, peroxidase, and O-dianisidine in determination of blood and urinary glucose.
متن کامل
Determination of blood glucose using an oxidase-peroxidase system with a non-carcinogenic chromogen.
Manual and automated methods for the determination of blood glucose have been devised using an oxidase/peroxidase system, with dl adrenaline, a non-carcinogen, as oxygen acceptor. The manual technique employs a stable single solution protein precipitant and the other reagents used are also stable. The automated methods are operated at 40/hr sample speed and washover between samples, over a very...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Interference by acetaminophen in the glucose oxidase-peroxidase method for blood glucose determination.
Acetaminophen, p-aminophenol, and oxyphenbutazone interfere with the glucose oxidase/peroxidase method for glucose. Structurally related compounds that lack a free phenolic hydroxyl group (acetanilide, aniline, and phenylbutazone) do not interfere. During the analytical procedure acetaminophen is consumed. One mole of acetaminophen leads to an apparent loss of four moles of glucose. The hexokin...
متن کاملDirect Automated Determination of Glucose by a Glucose Oxidase-peroxidase System.
THE DETERMINATION of glucose by the glucose oxidase-peroxidase system has been simplified by Hill and Kessler (2) with the use of an automated system first described by Skeggs (1). Wincy and Marks (3) have also developed a method using o-tolidine in the automated system. These procedures require a large quantity of sample and use of a dialyzer to separate the protein before color development. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemical and Pharmaceutical Bulletin
سال: 1979
ISSN: 0009-2363,1347-5223
DOI: 10.1248/cpb.27.568