Determination of four additives in cakes by large volume gradient ion chromatography
نویسندگان
چکیده
This paper aims to establish a detection method for simultaneous determining four additives in flour products: one simultaneously determines the acesulfame, sodium cyclamate, bromate, and calcium propionate through selection of ion chromatography pump flow rate, injection volume, eluent concentration, optimization sample pretreatment influence interfering ions. When using rate 0.8 ml/min, 200 µL large volume injection, 0-14 min, 14-25 min concentration 30 mmol/L gradient elution, 25-26 6 mmol/L, product is pulverized after addition water vortex ultrasonic extraction, supernatant by C18 solid phase extraction (SPE) columns silver filter, 0.22μm porous membrane testing on machine, limits kinds targets are 0.16 μg/ml, 0.19 0.24 0.38 respectively; The standard deviations retention time peak area propionate, respectively 0.13~0.42%, 2.14~4.25% ; bromate 0.20~0.67%, 1.33~4.52% cyclamate 0.14~0.53%, 3.57~5.62% acesulfame potassium 0.64~0.93%, 0.42~5.81%. uses as sole solvent can detect products single test. And process also very simple. it applied other food tests, some compounds may cause interference, which be assisted methods.
منابع مشابه
Simultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography
Background and objectives: High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP) in foodstuff by high performance liquid chromatography. Materi...
متن کاملDetermination of organochlorine pesticides in river water by gas chromatography-negative-ion chemical-ionization mass spectrometry using large volume injection
A method for the determination of 24 organochlorine pesticides by gas chromatography-mass spectrometry (GC-MS) with negative-ion chemical-ionization (NICI) using programmable temperature vaporizer (PTV)-based large volume injection (LVI) is described. The ion source temperature was determined to be 150 °C for the optimized NICI-selected ion monitoring (SIM) conditions. PTV inlet parameters were...
متن کاملThiocyanate determination by ion pair chromatography
Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania A simple and rapid ion pair chromatographic method has been developed for the determination of thiocyanate. Separation was carried out on a 25 cm × 4.6 mm Ascentis C18 column (5 μm particle size) with a mobile phase containing 2 mmol/l tetrabutylammonium (TBA)-phosphate (pH 6.5) ...
متن کاملDetermination of Trace Anions in High Purity Waters by High Volume/Direct Injection Ion Chromatography
INTRODUCTION There has been considerable interest in the determination of anions at trace levels by IC. For example, the Electric Power Research Institute (EPRI) has established IC as the analytical technique for determining sodium, chloride, and sulfate down to 0.25 μg/L (ppb) in power plant waters. For high-purity water used in semiconductor processing, the Semiconductor Equipment and Materia...
متن کاملextremal region detection guided by maxima of gradient magnitude
a problem of computer vision applications is to detect regions of interest under dif- ferent imaging conditions. the state-of-the-art maximally stable extremal regions (mser) detects affine covariant regions by applying all possible thresholds on the input image, and through three main steps including: 1) making a component tree of extremal regions’ evolution (enumeration), 2) obtaining region ...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2021
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202130001024