Determination of Fire Resistance of Eccentrically Loaded Reinforced Concrete Columns Using Fuzzy Neural Networks
نویسندگان
چکیده
منابع مشابه
Ambient and fire behaviour of eccentrically loaded elliptical slender concrete-filled tubular columns
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high te...
متن کاملFire Damage Assessment of Reinforced Concrete Structures Using Fuzzy Theory
Once a reinforced concrete (RC) structure is damaged by fire, the fire damage assessment should proceed to take appropriate post-fire actions, including the decision-making of whether it can be repaired for reuse or not. Since the assessment results of current fire damage diagnosis methods, however, highly depend on the subjective judgment of inspectors, it is hard to ensure their objectiveness...
متن کاملRehabilitation of Reinforced Concrete Columns
In recent years, rehabilitation has been the subject of extensive research due to increased spending on building work and repair of built works. In all cases, it is absolutely essential to carry out methods of strengthening or repair of structural elements, and that following an inspection analysis and methodology of a correct diagnosis. The reinforced concrete columns are important elements in...
متن کاملSeismic Response of Reinforced Concrete Columns
There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...
متن کاملThe Fire Resistance Performance of Recycled Aggregate Concrete Columns with Different Concrete Compressive Strengths
In order to ascertain the fire resistance performance of recycled aggregate concrete (RAC) components with different concrete compressive strengths, four full-scaled concrete columns were designed and tested under high temperature. Two of the four specimens were constructed by normal concrete with compressive strength ratings of C20 and C30, respectively, while the others were made from recycle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Complexity
سال: 2018
ISSN: 1076-2787,1099-0526