Determination of Fire Load and Heat Release Rate for High-rise Residential Buildings

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat Release Rate of an Open Kitchen Fire of Small Residential Units in Tall Buildings

In the Far East, many small units of residential buildings over 200 m tall are fitted with open kitchens. Fire safety provisions of these kitchens are determined by performance-based design (PBD). In most PBD projects, only the spread of smoke from the kitchen fire to the outside was studied. However, a fire load survey in Hong Kong indicated that large quantities of combustibles are stored in ...

متن کامل

Explanation of the physical factors affecting the mental image of residents of high-rise residential buildings

When dealing with a diverse and rich environment, humans record limited information in their minds, and this information forms a comprehensive, albeit inaccurate, mental image of the environment. On the other hand, living in high-rise residential buildings in Iran is always associated with dissatisfactions that a clear mental image in the minds of the residents can reduce these dissatisfactions...

متن کامل

Evaluation of Seismic Performance of Combined Horizontal and Vertical Hexagrid Structural System for High-rise Buildings

Summary In this study, the seismic performance of hexagrid structures which are composed of horizontal and vertical hexagrid by using a transitional story, has been investigated. To this end, 10 models of 50-story hexagrid structures were designed. 9 models with horizontal hexagrid cells which transited to vertical cells using a transitional story, and a model of completely horizontal hexagrid ...

متن کامل

Statistical analysis of baseline load models for non-residential buildings

Policymakers are encouraging the development of standardized and consistent methods to quantify the electric load impacts of demand response programs. For load impacts, an essential part of the analysis is the estimation of the baseline load profile. In this paper, we present a statistical evaluation of the performance of several different models used to calculate baselines for commercial build...

متن کامل

assessment of conventional nonlinear static procedures with fema load distributions and modal pushover analysis for high-rise buildings

the nonlinear static pushover analysis technique is mostly used in the performance-based design of structures and it is favored over nonlinear response history analysis. however, the pushover analysis with fema load distributions losses its accuracy in estimating seismic responses of long period structures when higher mode effects are important. some procedures have been offered to consider thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Procedia Engineering

سال: 2014

ISSN: 1877-7058

DOI: 10.1016/j.proeng.2014.10.460