Determination of Elements in Energy Drinks by ICP OES with Minimal Sample Preparation
نویسندگان
چکیده
منابع مشابه
Determination of Elements in Energy Drinks by ICP OES with Minimal Sample Preparation
Foram comparados vários procedimentos de preparo de amostras, isto é, decomposição total de uma mistura HNO3/H2O2 em placa de aquecimento, decomposição parcial por meio de solubilização em aqua regia e diluição com solução de HNO3 de baixa concentração, para determinação do conteúdo total de Ba, Ca, Cd, Cr, Cu, Fe, Mg, Mn, Ni, P, Pb, Sr e Zn em bebidas energéticas utilizando espectrometria de e...
متن کاملICP OES Determination of Contaminant Elements Leached from Food Packaging Films
Determination of potential contaminants elements in food packing films arising from contact with acidic aqueous foods was undertaken by inductively coupled plasma optical emission spectrometry (ICP OES) in accordance with DIN EN 1186-1. Test sections from plastic films were totally immersed in 3% w/v CH3COOH used as the food simulant. Testing was conducted under three conditions: (1) 10 days at...
متن کاملSimultaneous determination of trace rare-earth elements in simulated water samples using ICP-OES with TODGA extraction/back-extraction
The determination of trace rare-earth elements (REEs) can be used for the assessment of environmental pollution, and is of great significance to the study of toxicity and toxicology in animals and plants. N, N, N', N'-tetraoctyl diglycolamide (TODGA) is an environmental friendly extractant that is highly selective to REEs. In this study, an analytical method was developed for the simultaneous d...
متن کاملMinimization of sample volume with air-segmented sample injection and the simultaneous determination of trace elements by ICP-MS.
The application of inductively coupled plasma mass spectrometry (ICP-MS) to forensic chemistry was studied. The developed method, air-segmented sample injection (ASSI) coupled with ICP-MS, allowed the determination of about 25 elements at the sub-ppb level with only 0.2 ml of a sample solution. The optimum sample flow rate was found to be 0.4 ml min(-1), along with a sample suction time of 30 s...
متن کاملComparison method for uranium determination in ore sample by inductively coupled plasma optical emission spectrometry (ICP-OES).
A comparison method for the determination (without sample pre-concentration) of uranium in ore by inductively coupled plasma optical emission spectrometry (ICP-OES) has been performed. The experiments were conducted using three procedures: matrix matching, plasma optimization, and internal standardization for three emission lines of uranium. Three wavelengths of Sm were tested as internal stand...