Determination of diffusion coefficients by means of normal pulse polarography.
نویسندگان
چکیده
منابع مشابه
Trace Determination of Azathioprine by Differential Pulse Polarography
A simple and rapid differential pulse polarographic method was developed for the trace determination of azathioprine. A welldefined polarogram with three peaks was obtained in acetate buffer (pH 5.0) with peak potentials -0.27 V, -0.73 V and -1.02 V. The current-concentration linearity was found extend up to 5 x 10 mol L (r = 0.9992) with minimum detection limit of 2.8x10 mol L. The values of r...
متن کاملIndirect determination of thallium by differential-pulse polarography.
The method is based on the separation of Tl(I) as Tl(2)HPMo(12)O(40), stripping of the molybdate, and measurement of the peak current in differential-pulse polarography of the molybdenum. The calibration graph is linear over the range 2-12 ppm of thallium. The relative standard deviation is 1.2% (7 replicates each containing 500 microg of thallium). The current due to reduction of the molybdenu...
متن کاملSelective Determination of Trace-Bismuth by Extraction-Differential Pulse Polarography in Non-Aqueous Media
The voltammetric characteristics of bismuth(III)-oxinate in chloroform at the mercury electrode were investigated and a quasi-reversible behavior for Bi(III) oxinate reduction was confirmed. Preceded by the extraction of Bi(III) oxinate in chloroform, differential pulse polarography was developed in the extracts for determination of the trace-bismuth. The linear range of the calibration gra...
متن کاملDetermination of Selenium(IV) Using o-Phenylenediamine by Differential Pulse Polarography/Interference of Metal Ions
Determination of selenium in biological and environmental samples is usually difficult due to its trace or ultra-trace quantities, pre-concentration stages, destruction of organic matrices by acid digestion and oxygen plasma combustion followed by separation from interfering metal ions such as ion exchange separation, solvent extraction or hydride generation. Selective separation of selenium is...
متن کاملsimultaneous determination of zinc and lead in blood samples by differential pulse polarography
in present study we determine the zinc and lead levels in human blood samples by differential pulse polarography under optimum experimental conditions (ph=7.5, scan rate=5mv/s and pulse amplitude=50mv) the polarographic reduction peaks of zn and pb were examinedin the -0.72 v and-0.15 respectively. the zinc and lead content can be determined by in comparison with their standard solutions. accor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1990
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.6.239