DETERMINATION OF DIACETYL IN BEER USING DIFFERENTIAL-PULSE POLAROGRAPHY
نویسندگان
چکیده
منابع مشابه
Trace Determination of Azathioprine by Differential Pulse Polarography
A simple and rapid differential pulse polarographic method was developed for the trace determination of azathioprine. A welldefined polarogram with three peaks was obtained in acetate buffer (pH 5.0) with peak potentials -0.27 V, -0.73 V and -1.02 V. The current-concentration linearity was found extend up to 5 x 10 mol L (r = 0.9992) with minimum detection limit of 2.8x10 mol L. The values of r...
متن کاملSelective Determination of Trace-Bismuth by Extraction-Differential Pulse Polarography in Non-Aqueous Media
The voltammetric characteristics of bismuth(III)-oxinate in chloroform at the mercury electrode were investigated and a quasi-reversible behavior for Bi(III) oxinate reduction was confirmed. Preceded by the extraction of Bi(III) oxinate in chloroform, differential pulse polarography was developed in the extracts for determination of the trace-bismuth. The linear range of the calibration gra...
متن کاملIndirect determination of thallium by differential-pulse polarography.
The method is based on the separation of Tl(I) as Tl(2)HPMo(12)O(40), stripping of the molybdate, and measurement of the peak current in differential-pulse polarography of the molybdenum. The calibration graph is linear over the range 2-12 ppm of thallium. The relative standard deviation is 1.2% (7 replicates each containing 500 microg of thallium). The current due to reduction of the molybdenu...
متن کاملExtractive Differential Pulse Polarography of Mo (VI) Oxinate in Chloroform and its Application in the Determination of Molybdenum in Steel
The voltammetric characteristics of Mo (VI) oxinate at the mercury electrode, in the presence of tri-butylammonium perchlorate (tri-BAP) and piperidinium perchlorate (PP) + piperidine (P) as two different types supporting electrolytes, have been studied in chloroform. With the both supporting electrolytes a two electron irreversible process for the reduction of Mo (VI) oxinate was observe...
متن کاملDetermination of Selenium(IV) Using o-Phenylenediamine by Differential Pulse Polarography/Interference of Metal Ions
Determination of selenium in biological and environmental samples is usually difficult due to its trace or ultra-trace quantities, pre-concentration stages, destruction of organic matrices by acid digestion and oxygen plasma combustion followed by separation from interfering metal ions such as ion exchange separation, solvent extraction or hydride generation. Selective separation of selenium is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Institute of Brewing
سال: 1997
ISSN: 0046-9750
DOI: 10.1002/j.2050-0416.1997.tb00962.x