Determination of Deformable Image Registration Algorithms for Accumulating Dose in Carbon-ion Radiotherapy for Pancreatic Cancer

نویسندگان

چکیده

Background/Aim: This study aimed to determine appropriate deformable image registration (DIR) algorithms for pancreatic cancer patients undergoing carbon ion radiotherapy (CIRT). Patients and Methods: The performance of three types DIR algorithms, including intensity-based (iDIR), contour-based (cDIR), hybrid (hDIR) were evaluated using seventy-one CT images from eight patients. Both the geometry CTV subsequent dose warping discrepancies dice similarity coefficient (DSC) difference in V95. Results: cDIR hDIR had superior than iDIR both DSC V95 (p<0.0001). caused accumulated be underestimated by 5% median compared other methods. Conclusion: can utilized assess CIRT cancer. considered when obtained is greater 0.89.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Deformable Image Registration (DIR) Methods for Dose Accumulation in Nasopharyngeal Cancer Patients during Radiotherapy

Introduction Deformable image registration (DIR) is used to modify structures according to anatomical changes for observing the dosimetric effect. In this study, megavoltage computed tomography (MVCT) images were used to generate cumulative doses for nasopharyngeal cancer (NPC) patients by various DIR methods. The performance of the multiple DIR methods was analysed, and the impact of dose accu...

متن کامل

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

Evaluation of Deformable Image Registration Methods for Dose Monitoring in Head and Neck Radiotherapy

In the context of head and neck cancer (HNC) adaptive radiation therapy (ART), the two purposes of the study were to compare the performance of multiple deformable image registration (DIR) methods and to quantify their impact for dose accumulation, in healthy structures. Fifteen HNC patients had a planning computed tomography (CT0) and weekly CTs during the 7 weeks of intensity-modulated radiat...

متن کامل

Use of Deformable Image Registration for Radiotherapy Applications

In recent year, Deformable Image Registration (DIR) has become commercially available in the field of radiotherapy. DIR is an exciting and interesting technology for multi-modality image fusion, anatomic image segmentation, Four-dimensional (4D) dose accumulation and lung functional (ventilation) imaging. Furthermore, DIR is playing an important role in modern radiotherapy included Image-Guided...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Anticancer Research

سال: 2021

ISSN: ['0250-7005', '1791-7530']

DOI: https://doi.org/10.21873/anticanres.14836