Determination of cyanine dye Platonin by conductometric titration with tetraphenylborate.
نویسندگان
چکیده
منابع مشابه
Conductometric Titration Method for Determination of Alfuzosin Hydrochloride and Fexofenadine Hydrochloride Using Sodium Tetraphenylborate
A simple, precise and low cost conductometric method for the determination of alfuzosin hydrochloride and fexofenadine hydrochloride in pure form and pharmaceutical formulations using sodium tetraphenylborate has been described. The method is based on the formation of ion association complex of cations coming from the cited drugs with tetraphenylborate anions and the conductance of the solution...
متن کاملReview. Photooxygenation, photodegradation and antioxidative activity of platonin, a cyanine photosensitizing dye.
Platonin (4,4'-dimethyl-3,3'-di-n-heptyl-8-[2-(4methyl-3-n-heptylthiazole)] -2,2'-dicarbocyanine diiodine) is one of the photosensitive trithiazolepentamethine cyanine dyes. Visible light (VL)-promoted photodegradation products of platonin in an aqueous environment were identified as 3-heptyl4-methylthiazoline-2 -carbaldehyde (1), tetradecane-7-thiol (2), 1-nonene (3), heptylamine (4), 3-heptyl...
متن کاملStabilisation of a heptamethine cyanine dye by rotaxane encapsulation.
The crystal structure of a cyanine dye rotaxane shows that the cyclodextrin is tightly threaded round the polymethine bridge of the dye; encapsulation dramatically increases the kinetic chemical stability of the radicals formed on oxidation and reduction of the dye, making it possible to observe the rotaxane radical dication by ESR and UV-vis-NIR spectroscopy.
متن کاملMicrocomputer Automation of the Conductometric Titration of Hop Alpha-Acids
A general-purpose microcomputer was used to au tomate the determination of lead conductance value by titration. The microcumputer, presented with an extracted sample in a beaker, controls the addition of titrant and the taking of data, performs all calculations, and finally prints the corrected result along with a record of the titration. A number of operating parameters were studied in order t...
متن کاملConductometric titration of hydrochloric acid in gastric juice.
We describe a procedure for the determination of hydrochloric acid concentration in gastric juice by means of a conductometric titration of the 50-fold diluted sample with an aqueous ammonia solution. The conductometric method of endpoint indication leads to a definite location of the equivalence point in the titration of hydrochloric acid. The proposed method is simple and accurate and shows a...