Determination of Cr(III) and Cr(VI) by solvent extraction-atomic absorption spectrophotometry
نویسندگان
چکیده
منابع مشابه
Determination of mercury by atomic-absorption spectrophotometry.
A flameless atomic-absorption system has been developed for the determination of low concentrations of mercury in gaseous, solid and liquid samples of organic and inorganic materials.
متن کاملDetermination of Iron Species by Combination of Solvent Assisted-Dispersive Solid Phase Extraction and Spectrophotometry
A simple, rapid and sensitive solvent assisted-dispersive solid phase extraction method was developed for the extraction of iron(II) prior to its spectrophotometric determination. The Fe(II) reacted with 2,4,6-tris(2-pyridyl)-1,3,5-triazine, neutralized with sodium dodecyl sulfate and extracted onto the fine particles of benzophenone which were formed upon rapid injection of a mixture of benzop...
متن کاملDetermination of urinary manganese by the direct chelation-extraction method and flameless atomic absorption spectrophotometry.
The direct chelation-extraction method, originally developed by Hessel (1968) for blood lead analysis, has been successfully applied to urinalysis for manganese. The analyses of 35 urine samples containing up to 100 microgram/1 of manganese from manganese-exposed workers showed that the data obtained by this method agree well with those by wet digestion-flame atomic absorption spectrophotometry...
متن کاملDetermination of oxalic acid in urine by atomic absorption spectrophotometry.
A method is described for determination of oxalic acid in urine using atomic absorption spectrophotometry. The concentration of urinary oxalic acid is calculated by using the difference between two determinations of calcium: first, the excess of calcium in the supernatant after precipitation as calcium oxalate at pH 5, and second, the total calcium determined at pH less than 1 (endogenous and a...
متن کاملGas-sampling technique for arsenic determination by atomic absorption spectrophotometry.
IN CONVENTIONAL atomic absorption spectrophotometry a solution of the sample is introduced into the flame as an aerosol by means of a nebulizer. However, commercial nebulizers are only about 5 efficient in forming fine droplets suitable for atomization by the flame ( I ) . Furthermore, a solution aspirated at a usual rate of 3-5 ml/min for about 10 sec produces a concentration signal extending ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1975
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.24.723