Determination of cobalt in human biological liquids from electrothermal atomic absorption spectrometry

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of cadmium in wine by electrothermal atomic absorption spectrometry.

A method is described for direct electrothermal atomic absorption spectrometric (ETAAS) determination of cadmium in untreated samples of wine. Pyrolytic graphite tubes and graphite tubes with standard L'vov pyrolytic platforms were tested as atomizers. The detection limit achieved was 0.08 microg L(-1) Cd in wine. The relative standard deviation for the concentration range from 0.2 to 10 microg...

متن کامل

Determination of manganese in biological materials by electrothermal atomic absorption spectrometry: a review.

The great diversity of methods for measuring manganese in biological materials (serum, plasma, whole blood, urine, spinal fluid, and hair) reflects the difficulty in measuring extremely small quantities of this element. Detailed examination of these methods demonstrates that the one most used is flameless atomic absorption spectrometry. In this review we report the different instrument settings...

متن کامل

Improved determination of vanadium in biological fluids by electrothermal atomic absorption spectrometry.

We made sensitive and accurate electrothermal atomic absorption spectrometric measurements of vanadium in small volumes of serum. The wet-digested sample was extracted into an organic solvent, with N-benzoyl-N-(o-tolyl)hydroxylamine (BTA) as the chelating reagent. After evaporating the solvent, we dissolved the residue in acetic acid, and injected a 60-microL aliquot into a graphite furnace. In...

متن کامل

Determination of arsenic in biological fluids by electrothermal atomic absorption spectrometry.

A procedure for the determination of the total content of arsenic in urine, serum and blood by electrothermal atomic absorption spectrometry (ETAAS) is described. Zeeman correction is used to compensate the high background signals. The samples are diluted (1 + 1 for urine and 1 + 3 for both serum and blood samples) in a medium containing 0.1% w/v Triton X-100 before being introduced directly in...

متن کامل

Determination of Chromium in Biological Material by Electrothermal Atomic Absorption Spectrometry Method

Procedure for determination of chromium in biological materials by Zeeman graphite furnace atomic absorption spectrometry method using a Perkin-Elmer spectrometer equipped with hollow-cathode lamp at 357.9 nm was developed. The samples of animal tissues, food, and feed were digested in muffle furnace at 450oC. The ash was dissolved in 1 N hydrochloric acid and the final solution was diluted in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2009

ISSN: 1742-6596

DOI: 10.1088/1742-6596/182/1/012006