Determination of Chitosan by Cathodic Stripping Voltammetry
نویسندگان
چکیده
منابع مشابه
Determination of chitosan by cathodic stripping voltammetry.
A sensitive method for the determination of chitosan (CTS) by cathodic stripping voltammetry is presented. The method exploits a pair of oxidation-reduction peaks of CTS at -0.62 V (vs. SCE) and -0.54 V (vs. SCE), and an enhancement of the peak current of CTS observed in a 0.05 mol l(-1) potassium hydrogenphthalate buffer solution (pH 2.5). The peak current is linear with the concentration of C...
متن کاملDetermination of Aminophylline by Cathodic Stripping Voltammetry
Aminophylline is determined by cathodic stripping voltammetry (CSV) in BR buffer, pH 7.5 at a hanging mercury drop electrode. The detection limit was 3x10 M after 60 s accumulation at -0.60 V versus Ag/AgCl reference electrode. The linear range demonstrated up to 5x10 M using CSV. The interference caused by some purine derivatives, anions and some metal cations on the peak current was studied. ...
متن کاملDetermination of selenium by catalytic cathodic stripping voltammetry
A procedure is described for the determination of selenium in natural waters using cathodic stripping voltammetry in the presence of rhodium. Advantage is taken from a catalytic effect on the electrochemical reduction of protons in the presence of a mixed complex of selenide with rhodium and chloride, containing Cl–Rh–SeH species. The catalysis causes a very large peak-current at a negative pea...
متن کاملDetermination of abscisic acid by cathodic stripping square wave voltammetry.
In this paper a study is accomplished on behavior in a mercury electrode, of the phytohormone abscisic acid and of the conditions of accumulation in a HMDE. A mechanism is proposed of reduction based on its electrochemical behavior and proving the product of the reduction through mass spectrometry of bulks. A method is proposed for the determination of Abscisic acid (ABA) with a quantification ...
متن کاملDetermination of trace amounts of thallium by adsorptive cathodic stripping voltammetry with xylenol orange.
Trace amounts of thallium(I) can be determined using adsorptive cathodic stripping voltammetry in the presence of Xylenol Orange (XO). The reduction current of the thallium(I)-XO complex ion was measured by square-wave cathodic stripping voltammetry. The peak potential was at -0.44 V vs. Ag/AgCl. The effect of various parameters (pH, ligand concentration, accumulation potential and collection t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 2006
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.22.575