Determination of azide ion by ion chromatography with a graphitized carbon column.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of sodium azide in beverages by ion chromatography.

A convenient method for determination of sodium azide in beverages using ion chromatography is described. This method combines the specificity for azide with a simple sample preparation using a bubble and trap apparatus that removes any interferences. Sodium azide in a sample was acidified, and the azide was converted to the volatile hydrazoic acid, which was trapped in 2.5 mM sodium hydroxide ...

متن کامل

Determination of ammonium in seawater by column-switching ion chromatography.

A system which combines column switching and concentration was developed. A binary eluent mechanism was developed to study the effect of high sample concentration matrix on retention time shifts of the trace analyte. Separation conditions were chosen according to this mechanism to reduce the retention time shift of ammonium in the presence of high concentration sodium ion: high concentration su...

متن کامل

Determination of inorganic anions in natural water by microcolumn ion chromatography with on-column enrichment.

An on-column enrichment method was developed for the rapid determination of inorganic anions in natural water. The system was assembled from a syringe pump, a six-port switching valve with a sample-enrichment loop, a separation column and a UV detector. The enrichment efficiency of the system was tested by using inorganic anions as samples. The limits of detection were between 0.6 and 7.7 micro...

متن کامل

Thiocyanate determination by ion pair chromatography

Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania A simple and rapid ion pair chromatographic method has been developed for the determination of thiocyanate. Separation was carried out on a 25 cm × 4.6 mm Ascentis C18 column (5 μm particle size) with a mobile phase containing 2 mmol/l tetrabutylammonium (TBA)-phosphate (pH 6.5) ...

متن کامل

Photochemical degradation of azure-b with sulphate radical ion generated by peroxydisulphate ion with cupric ion

In this paper, the photochemical degradation of azure-b by Cu2+/S2O82− process has beenpresented. Cu2+ as photocatalyst and S2O82− ion as photooxidant used in this process. Atextremely low concentrations, cupric ion showed true catalytic activity in the overall process.The influence of various parameters on the performance of the treatment process has beenconsidered, such as pH, concentration o...