Determination of AC-DC difference in the 0.1-100 MHz frequency range
نویسندگان
چکیده
منابع مشابه
Thermal AC voltage standards with calculable AC-DC transfer difference in frequency range from 10 kHz to 1 MHz
Because Republic of Poland does not have its own primary AC voltage standard, we have been developing a set of standards which in the future can serve as national primary AC voltage standard. The set is composed of three standards with nominal input voltages UN of 1.5 V, 3 V and 6 V, respectively. The set covers AC voltage range from 0.7 V to 6 V. The voltage range will be extended to 0.5 ... 1...
متن کاملExtension of the NIST AC-DC Difference Calibration Service for Current to 100 kHz
The NIST calibration service for ac-dc difference of thermal current converters relies on multijunction thermal converters as the primary standards, and various thermal converters and thermoelements (TEs) as the reference and working standards. Calibrations are performed by comparing the ac-dc difference of a customer's thermal current converter to the ac-dc difference of a NIST standard curren...
متن کاملTwo efficient methods for measuring hydrophone frequency response in the 100 kHz to 2 MHz range
As new medical applications of ultrasound emerge with operating frequencies in the hundreds of kilohertz to low megahertz region, it becomes more important to have convenient calibration methods for hydrophones in this frequency range. Furthermore, short diagnostic ultrasound pulses affected by finite amplitude distortion require that the hydrophone frequency response be known well below the ce...
متن کاملdetermination of maximal singularity free zones in the workspace of parallel manipulator
due to the limiting workspace of parallel manipulator and regarding to finding the trajectory planning of singularity free at workspace is difficult, so finding a best solution that can develop a technique to determine the singularity-free zones in the workspace of parallel manipulators is highly important. in this thesis a simple and new technique are presented to determine the maximal singula...
15 صفحه اولShielded Cable Transfer Impedance Measurements High frequency range 100 MHz–1 GHz
©2011 IEEE Plotting the individual components is shown in Fig. 11. Adding the pulses gives the solution for V 10, t 2 shown in Fig. 12. All of the results of the above examples were validated using the PSPICE circuit analysis computer program. Use of the exact lossless transmission line model in PSPICE for more complicated lossless transmission-line problems is highly recommended [1]. VI. Refer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Instrumentation and Measurement
سال: 1989
ISSN: 0018-9456
DOI: 10.1109/19.192307