Determinants of myocardial conduction velocity: implications for arrhythmogenesis
Slowed myocardial conduction velocity (θ) is associated with an increased risk of re-entrant excitation, predisposing to cardiac arrhythmia. θ is determined by the ion channel and physical properties of cardiac myocytes and by their interconnections. Thus, θ is closely related to the maximum rate of action potential (AP) depolarization [(dV/dt)max], as determined by the fast Na(+) current (I Na...
متن کاملComputational Representations of Myocardial Infarct Scars and Implications for Arrhythmogenesis
Image-based computational modeling is becoming an increasingly used clinical tool to provide insight into the mechanisms of reentrant arrhythmias. In the context of ischemic heart disease, faithful representation of the electrophysiological properties of the infarct region within models is essential, due to the scars known for arrhythmic properties. Here, we review the different computational r...
متن کاملThe role of myocardial gap junctions in electrical conduction and arrhythmogenesis.
Electrical activation of the heart requires cell-cell transfer of current via gap junctions, arrays of densely packed protein channels that permit intercellular passage of ions and small molecules. Because current transfer occurs only at gap junctions, the spatial distribution and biophysical properties of gap junction channels are important determinants of the conduction properties of cardiac ...
متن کاملMyocardial architecture and ventricular arrhythmogenesis.
Conduction of the cardiac impulse is dependent on both the active membrane properties of cardiac cells (generating the action potential) and the passive properties determined by architectural features of the myocardium. The influence of tissue architecture on conduction is determined principally by the size, shape, and packing of individual myocytes and by the quantity, three-dimensional distri...
متن کاملConduction velocity costs energy
Hodgkin and Adrian’s 1975 hypothesis that the squid axon is optimized for maximum conduction velocity is flawed by (i) the inaccurate value of its prediction for channel density, and (ii) the prohibitive energetic expense entailed by their prediction. Here we investigate the metabolic cost of conduction velocity. By manipulating ion channel density or by manipulating the Nernst battery voltages...