Detector Calibration
نویسندگان
چکیده
Abstract The information needed when analysing data, for example, the cross-section measurements, is 4-momentum vectors of particles in interest, and possibly knowledge about species particles. For this purpose, detector high energy physics usually designed so that it allows us to measure momentum or energy, particle identification, such as velocity. However, recorded data they are do not tell anything. They just a bunch digits which energies positions if properly translated into meaningful physical variables.
منابع مشابه
The MuLan Detector Calibration System
The MuLan experiment has been designed to make a precision measurement of the muon lifetime to one part per million. The experiment uses 340 scintillation detectors to detect the positron produced in the muon's decay. Members of the James Madison University Physics department have been responsible for the design and implementation of a calibration system for the MuLan detector. The calibration ...
متن کاملCMS Silicon Pixel Detector Calibration
The Compact Muon Solenoid (CMS) pixel group at Cornell University is building a silicon pixel detector test station that will model the detection and data acquisition system designed for the CMS experiment at the Large Hardron Collider (LHC) at CERN. With parts of the apparatus already functional, we have begun to understand and optimize the detector’s programmable settings, called DACs, that t...
متن کاملCalibration of the ALICE Transition Radiation Detector
The Transition Radiation Detector (TRD) belongs to the central barrel detectors of the ALICE experiment at the LHC at CERN. It is composed of 540 large area drift chambers, with a total of 1181952 readout pads (1728 or 2304 per chamber). To ensure the optimal performance of the detector, designed for electron/pion identification and charged particle tracking, including triggering for high-pt el...
متن کاملTwin-photon techniques for photo-detector calibration
The aim of this review paper is to enlighten some recent progresses in quantum optical metrology in the part of quantum efficiency measurements of photo-detectors performed with bi-photon states. The intrinsic correlated nature of entangled photons from Spontaneous Parametric Down Conversion phenomenon has opened wide horizons to a new approach for the absolute measurement of photodetector quan...
متن کاملOn the Calibration of Ultrasonic Flaw Detector
For the assessment performance of the ultrasonic flaw detector (UFD) equipment, various standard documents are referred to such as ASTM (E317), British Standard (BS-4331), Bureau of Indian Standard (IS-12666), and more. The methods of calibration are spelt in different tone in these documents while broadly serving the same purpose. In the present paper a comparison for the calibration procedure...
متن کاملذخیره در منابع من