Detection of thymoma on 99mtc mibi scintigraphy: Revisiting the past

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

99mTc-MIBI scintigraphy in musculoskeletal tumors.

UNLABELLED The aim of this study was to assess the value of 99mTc-hexakis2-methoxyisobutylisonitrile (MIBI) scintigraphy in patients with clinical and radiologic features of primary or metastatic musculoskeletal tumors. METHODS The scintigraphic findings for 84 patients were compared with the surgical and histologic findings. Each patient underwent three-phase bone scanning with 99mTc-methyle...

متن کامل

99mTc-MIBI scintigraphy in musculoskeletal tumors [Persian]

The aim of this study was to assess the value of 99mTc-hexakis-2-methoxyisobutylisonitrile (MIBI) scintigraphy in patients with clinical and radiologic features of primary or metastatic musculoskeletal tumors. Methods: The scintigraphic findings for 84 patients were compared with the surgical and histologic findings. Each patient underwent three-phase bone scan with 99mTc-methylene diphos...

متن کامل

99mTc-MIBI scintigraphy in the diagnosis of multiple myeloma.

POLSKIE ARCHIWUM MEDYCYNY WEWNĘTRZNEJ 2016; 126 (3) MM is characterized by malignant proliferation of clonal plasma cells and excessive formation of monoclonal immunoglobulin.1 99mTc-MIBI is a radiotracer commonly used in myocardial perfusion imaging (FIGURE 1C). In literature, there have been reports on the use of 99mTc-MIBI in the diagnosis of MM since 1996.2 In a multicenter study conducted ...

متن کامل

99mtc-mibi scintigraphy in musculoskeletal tumors [persian]

the aim of this study was to assess the value of 99mtc-hexakis-2-methoxyisobutylisonitrile (mibi) scintigraphy in patients with clinical and radiologic features of primary or metastatic musculoskeletal tumors. methods: the scintigraphic findings for 84 patients were compared with the surgical and histologic findings. each patient underwent three-phase bone scan with 99mtc-methylene diphosphonat...

متن کامل

The role of 99mTc-MIBI scintigraphy in the management of patients with pulmonary tuberculosis.

BACKGROUND This study aimed to determine whether 99mTc-methoxyisobutylisonitrile (MIBI) scanning could improve diagnostic accuracy of pulmonary tuberculosis (PTB) and help clinical decision making for an accurate management. MATERIAL AND METHODS 99mTc-MIBI scintigraphy was performed in 62 cases of PTB 34 cases had active pulmonary tuberculosis (APTB) and were at the beginning of antituberculo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Indian Journal of Nuclear Medicine

سال: 2017

ISSN: 0972-3919

DOI: 10.4103/0972-3919.198484