Detection of subarachnoid and intravascular epidural catheter placement
نویسندگان
چکیده
منابع مشابه
Strategic placement of epidural catheter
Corresponding author: Jae-Hang Shim, M.D., Ph.D., Department of Anesthesiology and Pain Medicine, Hanyang University Hospital, 249-1, Gyomun-dong, Guri 471-701, Korea. Tel: 82-31-560-2390, Fax: 82-31-563-1731, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by...
متن کاملPredistention of the epidural space before catheter insertion reduces the incidence of intravascular epidural catheter insertion.
BACKGROUND Accidental cannulation of an epidural vein is a common complication associated with epidural anesthesia or analgesia. On the basis of a pilot study and previous reports, we tested the hypothesis that predistention of the epidural space with saline before epidural catheterization would ease catheter insertion and decrease the incidence of this complication. METHODS Two-hundred-three...
متن کاملIntravascular migration of a previously functioning epidural catheter
Corresponding author: Hea-Jo Yoon, M.D., Department of Anesthesiology and Pain Medicine, Cheil General Hospital, Kwandong Uiversity Medical School, 1-19, Mukjeong-dong, Jung-gu, Seoul 100-380, Korea. Tel: 82-2-2000-7822, Fax: 82-2-2000-7477, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:/...
متن کاملEffect of sleep deprivation on labour epidural catheter placement.
BACKGROUND Epidural catheter insertion for labour analgesia is an invasive procedure with potential serious complications, often performed by a sleep-deprived clinician. The aim of this study was to examine the effects of sleep deprivation on physicians of variable levels of experience performing this procedural skill in the clinical setting. METHODS After institutional review board approval,...
متن کاملConfirmation of epidural catheter placement using nerve stimulation.
PURPOSE To examine the reliability of low current electrical epidural stimulation to confirm epidural catheter placement. METHODS Forty patients with epidural catheters (19G Arrow Flextip plus) already in place for post-operative pain management were studied. An adapter (Arrow-Johans ECG Adapter) was attached to the connector of the epidural catheter. The epidural catheter and adapter were fi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Journal of Anesthesia/Journal canadien d'anesthésie
سال: 1999
ISSN: 0832-610X,1496-8975
DOI: 10.1007/bf03013957