Detection of power transformer bushing faults and oil degradation using frequency response analysis
نویسندگان
چکیده
منابع مشابه
Transformer Fault Detection Using Frequency Response Analysis
Power transformers prove to be a vital element or tool in electrical power supply and transmission system. They are capital intensive units and need to be monitored for faults. Faults in transformers leading to their failure are repugnant. Thus, there is a need to detect such faults at an initial level. This paper aims to detect, diagnose the nature and cause of mechanical faults, their identit...
متن کاملClassification of transformer faults using frequency response analysis based on cross-correlation technique and support vector machine
One of the most important methods for transformers fault diagnosis (especially mechanical defects) is the frequency response analysis (FRA) method. The most important step in the FRA diagnostic process is to differentiate the faults and classify them in different classes. This paper uses the intelligent support vector machine (SVM) method to classify transformer faults. For this purpose, two gr...
متن کاملDetection of power oscillation and simultaneous faults using Clark transform
Distance relays are widely used to protect transmission lines. Sometimes, in these lines due to the occurrence of the oscillation of the power, the impedance calculated in the distance relay enters into its functional zones and leads to the cutting off of the lines. This issue can cause global power outages. Accordingly, in this paper, a Clark-based method for detecting the oscillation of power...
متن کاملPower Transformer Incipient Faults Monitoring
Power transformers are important and expensive components in the electric power system. The knowledge of the actual status of the transformer insulation behavior, load tap changer performance, temperature, and load condition is necessary in order to evaluate the service performance concerning reliability, availability and safety. Systems abnormalities, loading, switching and ambient condition n...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Dielectrics and Electrical Insulation
سال: 2016
ISSN: 1070-9878
DOI: 10.1109/tdei.2015.005032