Detection of Low Blood Hemoglobin Levels on Pulmonary CT Angiography: A Feasibility Study Combining Dual-Energy CT and Machine Learning

نویسندگان

چکیده

Objectives: To evaluate if dual-energy CT (DECT) pulmonary angiography (CTPA) can detect anemia with the aid of machine learning. Methods: Inclusion 100 patients (mean age ± SD, 51.3 14.8 years; male-to-female ratio, 42/58) who underwent DECT CTPA and hemoglobin (Hb) analysis within 24 h, including 50 cases Hb below controls ≥ 12 g/dL. Blood pool attenuation was assessed on virtual noncontrast (VNC) images at eight locations. A classification model using extreme gradient-boosted trees developed a training set (n = 76) for differentiating from controls. The best evaluated in separate test 24). Results: significantly lower than (p-values < 0.01), except right atrium (p 0.06). learning had sensitivity, specificity, accuracy 83%, 92%, 88%, respectively. Measurements descending aorta highest relative importance among all features; threshold 43 HU yielded 68%, 76%, 72%, Conclusion: VNC imaging shows good diagnostic performance detecting CTPA.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study

BACKGROUND Computed tomography (CT) low-dose (LD) imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems. PURPOSE To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA). MATERIAL AND METHO...

متن کامل

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

Dual Energy CT Pulmonary Angiography with 6g Iodine—A Propensity Score-Matched Study

OBJECTIVE To evaluate the performance of low contrast media (CM) dose dual-energy computed tomography pulmonary angiography (CTPA) with advanced monoenergetic reconstructions in patients with suspected pulmonary embolism (PE). MATERIALS AND METHODS The study had institutional review board approval; all patients gave written informed consent. Forty-one patients (25 men, 16 women, mean age 62.9...

متن کامل

Dual energy CT pulmonary angiography: findings in a patient with chronic thromboembolic pulmonary hypertension.

A 55-year-old woman became increasingly breathless over a 9month period. Systolic pulmonary artery pressure was estimated at 50 mm Hg by echocardiography. CT pulmonary angiography was performed using a dual energy technique whereby datasets are simultaneously acquired at 80 kV and 140 kV. Differential absorption of these energy spectra by iodine molecules in intravenous contrast medium is explo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Tomography

سال: 2023

ISSN: ['2379-1381', '2379-139X']

DOI: https://doi.org/10.3390/tomography9040123