Detection of awareness in surgical patients with EEG-based indices--bispectral index and patient state index.
BACKGROUND Patient state index (PSI) and bispectral index (BIS) are values derived from the EEG, which can measure the hypnotic component of anaesthesia. We measured the ability of PSI and BIS to distinguish consciousness from unconsciousness during induction and emergence from anaesthesia and a period of awareness in surgical patients. METHODS Forty unpremedicated patients were randomized to...
متن کاملEEG-based indices of anaesthesia: correlation between bispectral index and patient state index?
BACKGROUND AND OBJECTIVE Both the bispectral and the patient state indices are derived from the electroencephalogram and have been proposed as a measure of the same clinical target, the hypnotic component of anaesthesia. The present study evaluated whether there is concordance between the bispectral and the patient state indices with regard to end-points measured simultaneously in patients unde...
متن کاملmodern surgical techniques in treatment of patients with cleft lip & cleft palate
چکیده ندارد.
15 صفحه اولAwareness and Satisfaction of Patients with Iranian Patient Package Inserts
Background and purpose: A drug brochure or Patient Package Insert (PPI) is a folded sheet of paper in drug package that provides necessary information for effective and safe use of the drug. PPIs are one of the main sources of drug information, so, they should be clear and easily comprehensible to the general public. The purpose of this study was to determine the awareness and satisfaction of p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Anaesthesia
سال: 2003
ISSN: 0007-0912
DOI: 10.1093/bja/aeg188