Detection of Anti-SSA Antibodies by Indirect Immunofluorescence
نویسندگان
چکیده
منابع مشابه
Detection of anti-SSA antibodies by indirect immunofluorescence.
BACKGROUND HEp-2 cells that overexpress the human 60-kDa SSA antigen have been used to improve sensitivity and specificity for the detection of anti-SSA antibodies by indirect immunofluorescence. We describe a survey on the detection of anti-SSA antibodies using a commercial substrate that overexpresses SSA. METHODS The evaluation was done on 18 371 consecutive samples submitted to the labora...
متن کاملCorrection: Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies
Reference 1. Mahler M, Ngo JT, Schulte-Pelkum J, Luettich T, Fritzler MJ: Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies. Arthritis Res Ther 2008, 10:R131. Correction Correction: Limited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies Michael Mahler1, Jennifer T Ngo2, Johannes Schult...
متن کاملIndirect immunofluorescence test for the detection of Aspergillus fumigatus antibodies.
An indirect immunofluorescence test was both sensitive and specific in detecting IgG antibodies to Aspergillus fumigatus. The test revealed a significant increase in titre of antibodies in patients with the allergic or mycetomal forms of pulmonary aspergillosis.
متن کاملLimited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies
INTRODUCTION Autoantibodies to the ribosomal P proteins represent a highly specific marker for the diagnosis of systemic lupus erythematosus, where they have been associated with certain clinical manifestations. Historically, autoantibodies against ribosomal P proteins have been detected by indirect immunofluorescence, immunodiffusion, immunoblot, and other immunoassays. More recently, enzyme-l...
متن کاملAnti-RNA polymerase III antibodies in patients with systemic sclerosis detected by indirect immunofluorescence and ELISA
OBJECTIVES To evaluate the analytical performance of an ELISA for the detection of anti-RNA polymerase III antibody (ARA) and to assess IIF as a method for identifying this antibody. METHODS A commercially available ELISA was used to assess the presence of ARA in sera from 1018 SSc patients. The sera had been divided into sub-populations based on the presence of specific autoantibodies, ANA p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 2004
ISSN: 0009-9147,1530-8561
DOI: 10.1373/clinchem.2004.035964