Detailed analysis of grid connected and islanded operation modes based on P/U and Q/f droop characteristics

نویسندگان

چکیده

This paper presents a thorough control structure of the distributed generators inside microgrid during both grid-connected and islanded operation modes. These structures DGs voltage source inverters are implemented in synchronous reference frame (SRF) controlled using linear PI controllers. By implementing structures, desired real reactive power can be efficiently transferred to local loads utility load by generating units. A modified droop technique is introduced facilitate performance modes operation. The active sharing demand between grid performed this drop mode. system intentional islanding event increase investigated. effectiveness offered confirmed through simulation results

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Riding-through Technique for Seamless Transition between Islanded and Grid-Connected Modes of Droop-Controlled Inverters

Abstract: This paper presents a seamless transition method for a droop-controlled inverter. The droop control is suitable to make the inverter work as a voltage source in both islanded and grid-connected modes, however, the transfer between theses modes can result in a big inrush current that may damage the system. The proposed method allows the droop-controlled inverter to improve the transien...

متن کامل

Power Management in Microgrid: Analysis in Grid Connected and Islanded Mode of Operation

Received Sep 4, 2017 Revised Oct 21, 2017 Accepted Nov 18, 2017 This paper presents an investigation about the impact of integrating renewable energy based generation sources on the existing distribution system in terms of load sharing. The study of load sharing among various distributed generators (DGs) and utility grid has been performed for two cases: (a) when equivalent source based DG is c...

متن کامل

Load-following performance analysis of a microturbine for islanded and grid connected operation

Modeling, simulation and performance analysis of a microturbine (MT) generator (MTG) system is carried out in this paper. The MTG system is consisting of a MT coupled with a synchronous generator. The proposed model incorporates power, speed and voltage controller for maintaining constant speed and voltage under variable loading condition. Modeling and simulation tasks are performed in MATLABSI...

متن کامل

effect of bataine and sulphate supplement on wool and milk characteristics and lambs performance in naine ewes

تعداد 20 رأس میش نژاد نائینی 6+-24 ماهه، با میانگین وزن 2/3-+40 کیلوگرم، همراه با 20 رأس بره های آنها در قالب طرح کاملا تصادفی اثر بتائین و مکمل سولفات بر خصوصیات شیر و پشم و عملکرد بره ها بررسی شد. میش ها بطور تصادفی در چهار تیمار قرار گرفتند. تیمارها عبارت بودند از: 1-گروه شاهد 2-بتائین (05/0 درصد ماده خشک) 3-سولفات (24/0 سولفور درصد ماده خشک 4-بتائین هرماه با سولفات. جیره غذائی طبق nrc با مح...

15 صفحه اول

Coordinated Control Strategy for Microgrid in Grid-Connected and Islanded Operation

As usual, the microgrid operates in grid-connect mode, but, when a fault occurs in the upstream grid, it should disconnect and shift into islanded operation mode. In grid-connect mode, the controlling power at the PCC is necessary management function rather than the frequency and voltage. However, the controlling the frequency and voltage is asked in islanded mode. To achieve these management g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Power Electronics and Drive Systems

سال: 2021

ISSN: ['2722-2578', '2722-256X']

DOI: https://doi.org/10.11591/ijpeds.v12.i2.pp772-782