The need to produce intense X-rays in the Energy Recovery Linear Accelerator requires shorter and narrower electron beams than the Cornell Electron Storage Ring can provide. Such electron beams will demand highly accurate beam position monitors (BPMs) to enable operators to control the beam. To prepare for new BPMs, a test stand has been built to conduct experiments on new algorithms and design...
متن کاملDesign of the Button Beam Position Monitor for Pep-ii
* Work supported by US Department of Energy, contract number DE-AC03-76F00515. Presented at the US Particle Accelerator Conference and International Conference on High-Energy Accelerators (PAC95), Dallas TX, USA, May 1995 The beam position monitor (BPM) was designed to provide a robust UHV feedthru and a reliable electromagnetic sensor. Stringent resolution requirements at low beam currents, bu...
متن کاملNew Beam Position Monitor System Design for the APS Injector*
Demands on the APS injector have evolved over the last few years to the point that an upgrade to the existing beam position monitor (BPM) electronics is required. The injector is presently being used as a source for both the low-energy undulator test line (LEUTL) project and the top-up mode of operation. These new requirements and the fact that many new rf receiver components are available at r...
متن کاملPerformance of the Beam Position Monitor System of the Final Focus Test Beam
The Beam Position Monitor BPM system for the Final Focus Test Beam FFTB at SLAC is designed to meet challenging speciications in the areas of single-pulse resolution, ab initio installation accuracy, and time-stability of BPM electrical centroids. We review the tolerances on these quantities and the technical choices made to achieve same, and detail the results of several studies of the actual ...
متن کاملBeam Position Monitor System of DAΦNE
The DAΦNE beam position monitor (BPM) system consists of 150 monitors installed all along the machine. Design issues, calibration procedures, experimental results and performance of the system are described. The closed orbit in the main rings is extracted from the BPM signals through narrowband receivers (realized by Bergoz Precision Beam Instrumentation for DAΦNE), then acquired and processed ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Special Topics - Accelerators and Beams
سال: 2010
ISSN: 1098-4402
DOI: 10.1103/physrevstab.13.032801