Design of trip current monitoring system for circuit breaker condition assessment
نویسندگان
چکیده
منابع مشابه
Trip Coil Signature Analysis and Interpretation for Distribution Circuit Breaker Condition Assessment and Diagnosis
A circuit breaker may be considered an ‘active link’, used to make and break an electrical circuit under conditions of varying severity. In the event of a circuit fault the circuit breaker must respond within tens of milliseconds in order to prevent damage to connected plant and safeguard personnel. As such, a circuit breaker will remain idle for the bulk of its lifetime, only being called into...
متن کاملsimulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولONLINE CIRCUIT BREAKER MONITORING SYSTEM A Thesis
Online Circuit Breaker Monitoring System. (December 2007) Zarko Djekic, B.S., University of Novi Sad, Serbia Chair of Advisory Committee: Dr. Mladen Kezunovic Circuit breakers are used in a power system to break or make current flow through power system apparatus. Reliable operation of circuit breakers is very important to the well-being of the power system. Historically this is achieved by reg...
متن کاملDevelopment of an Overall Condition Monitoring System of High Voltage SF6 Circuit Breaker
With the rapid development of arts of sensors and IT, on-line monitoring of circuit breaker is now desirable and practical for electric power utilities. This paper describes a set of overall on-line monitoring systems that was developed to control and monitor the condition of SF6 circuit breaker with different type of sensors and microcomputer based controller. The aim of the developed system i...
متن کاملPower system monitoring based on relay and circuit breaker information
In this paper we develop monitoring schemes that are able to detect and identify failures in power transmission lines by analyzing binary status information from relays and circuit breakers. The approach, which is based on Petri net models, requires very simple calculations (linear checks) during execution time and allows for concurrent/incremental processing of the information as it arrives at...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IET Generation, Transmission & Distribution
سال: 2007